Logo do repositório
 
Publicação

Comportamento de diferentes chaves de torque usadas em prótese sobre implantes

datacite.subject.fosCiências Médicas::Outras Ciências Médicaspt_PT
dc.contributor.advisorCorreia, André Ricardo Maia
dc.contributor.advisorAraújo, Filipe Miguel Soares Framegas de
dc.contributor.authorMacário, Jorge Daniel Almeida
dc.date.accessioned2022-09-09T14:25:00Z
dc.date.available2022-09-09T14:25:00Z
dc.date.issued2022-07-15
dc.date.submitted2022
dc.description.abstractIntrodução: Os torquímetros, ou chaves de torque, são indispensáveis na reabilitação oral protética com implantes dentários. Existem vários tipos de torquímetros manuais, dos quais se destacam os toggle-style e os spring-style. O principal objetivo desta investigação foi analisar e avaliar o comportamento mecânico de dois torquímetros diferentes em prótese sobre implantes. Materiais e Métodos: Para a realização deste estudo, foram utilizados dois torquímetros com sistemas dinamométricos diferentes, spring-style e togglestyle. O estudo para cada torquímetro foi efetuado em 3 mesas de trabalho, montadas cada uma com análogo, pilar standard reto e parafuso reto. Para cada torquímetro foram feitos 30 ciclos de aperto/desaperto para os valores préselecionados, 10, 20 N.cm e 35 N.cm., e anotado o valor medido por uma célula de medição de binário. Foi realizado um estudo estatístico descritivo e inferencial. Resultados: Segundo a média, ambos os torquímetros apresentaram valores inferiores ao torque pré-selecionado, exibindo resultados significativamente diferentes. O mesmo se pode confirmar segundo a análise entre os dois sistemas toggle-style e spring-style, dado que ambos demonstraram ser significativamente diferentes. O toggle-style obteve sempre valores inferiores ao spring-style. No entanto, segundo a análise de variância, os dois torquímetros apresentaram semelhanças, tendo assim uma dispersão de torque similar. Conclusão: Dentro das limitações deste estudo, podemos concluir que os dois torquímetros analisados apresentaram valores de torque inferiores aos préselecionados. Verificou-se também que o tipo de sistema mecânico do torquímetro também pode originar valores de torque distintos.pt_PT
dc.description.abstractIntroduction: Torque wrenches are indispensable in a prosthetic oral rehabilitation with dental implants. There are several types of manual torque wrenches, of which toggle-style and spring-style stand out. The main objective of this research was to analyze and evaluate the mechanical behavior of two different torque wrenches used in a prosthetic oral rehabilitation with dental implants. Materials and Methods: A laboratory study was carried out to test the mechanical behavior of two torque wrenches with different dynamometric systems, spring-style and toggle-style. For each torque wrench it was prepared 3 working tables with an analogue, straight standard abutment and straight screw. For each torque wrench, 30 tightening/loosening cycles were performed for the pre-selected values, 10, 20 N.cm and 35 N.cm, and recorded the value measured by a torque measurement cell. A descriptive and inferential statistical analysis was carried out. Results: According to the average, both presented values lower than the preselected torque, showing significantly different results. The same can be confirmed according to the toggle-style and spring-style systems, since both proved to be significantly different. Toggle-style was always inferior to springstyle. However, according to the variance, the two torquemeters showed similarities, thus having a similar torque dispersion between them. Conclusion: Within the limitations of this research, it can be concluded that the analyzed torque wrench systems presented inferior values to those pre-selected. Also, the type of dynamometric system can also give different torque values.pt_PT
dc.identifier.tid203051866pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.14/38805
dc.language.isoporpt_PT
dc.subjectImplantes dentáriospt_PT
dc.subjectTorquept_PT
dc.subjectTensões mecânicaspt_PT
dc.subjectTorquímetropt_PT
dc.subjectDental implantspt_PT
dc.subjectTorquept_PT
dc.subjectMechanical stresspt_PT
dc.subjectTorque wrenchpt_PT
dc.titleComportamento de diferentes chaves de torque usadas em prótese sobre implantespt_PT
dc.typemaster thesis
dspace.entity.typePublication
rcaap.rightsopenAccesspt_PT
rcaap.typemasterThesispt_PT
thesis.degree.nameMestrado em Medicina Dentáriapt_PT

Ficheiros

Principais
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
203051866.pdf
Tamanho:
1.45 MB
Formato:
Adobe Portable Document Format
Licença
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
203051866.txt
Tamanho:
3.44 KB
Formato:
Item-specific license agreed upon to submission
Descrição: