Repository logo
 
Publication

A influĂȘncia da broca plana em cirurgia de implantes parcialmente guiada

datacite.subject.fosCiĂȘncias MĂ©dicas::CiĂȘncias da SaĂșde
dc.contributor.advisorFonseca, PatrĂ­cia Alexandra Barroso da
dc.contributor.advisorFonseca, Catarina Mendes
dc.contributor.authorFerreira, Ana Raquel Veloso Nogueira
dc.date.accessioned2025-08-06T14:21:44Z
dc.date.available2025-08-06T14:21:44Z
dc.date.issued2025-07-18
dc.date.submitted2025
dc.description.abstractIntrodução: A cirurgia de implantes parcialmente guiada visa aumentar a precisĂŁo clĂ­nica do ato cirĂșrgico. Este estudo, tem como principal objetivo analisar o impacto da broca plana na precisĂŁo espacial da colocação de implantes Bone Level (BL) no protocolo cirĂșrgico parcialmente guiado. Secundariamente, pretende-se avaliar a influĂȘncia da densidade Ăłssea e da macrogeometria do implante nessa precisĂŁo. Materiais e MĂ©todos: ApĂłs cĂĄlculo amostral, foram colocados 120 implantes (StraumannÂź BL, BLT e BLX) em blocos homogĂ©neos de poliuretano simulando quatro nĂ­veis de densidade Ăłssea (D13D4). A preparação do leito implantar foi realizada com recurso a guias cirĂșrgicas seguindo um protocolo cirĂșrgico guiado, com ou sem o auxĂ­lio da broca plana. JĂĄ a colocação dos implantes foi feita sem recurso a guia cirĂșrgica. As discrepĂąncias entre as posiçÔes planeadas virtualmente no software coDiagnostiXÂź e as posiçÔes finais obtidas foram avaliadas com a ferramenta <Treatment Evaluation= do referido software, analisando desvios tridimensionais e angulares ao nĂ­vel do colo e do ĂĄpice do implante. A anĂĄlise estatĂ­stica recorreu ao software IBMÂź SPSSÂź Statistics v. 24., para um nĂ­vel de significĂąncia de p<0,05. Resultados: Numa anĂĄlise geral, os maiores desvios tridimensionais foram observados a nĂ­vel do ĂĄpice (0,88mm) comparativamente com o colo do implante (0,56mm), sem utilização da broca plana. A utilização da broca plana diminuiu, de forma estatisticamente significativa (p=0,007), o desvio angular na colocação dos implantes (de 3,40ÂĄ para 2,45ÂĄ). No que concerne Ă  densidade Ăłssea, apesar de nĂŁo identificarmos diferenças significativas no desvio angular, este foi maior para o osso D4 (3,60ÂĄ). Registamos diferenças significativas ao nĂ­vel do colo do implante quer tridimensionalmente (p=0,027; osso D3=0,40mm; osso D1=0,99mm), quer linearmente nos sentidos mesio-distal (p=0,036; osso D2/D3=0,08mm; osso D1=0,12mm) e buco-lingual (p<0,001; osso D3=0,06mm; osso D1=0,58mm). Quando analisado o ĂĄpice do implante, apenas encontramos significĂąncia para os desvios lineares no sentido apico-coronal (p=0,005), sendo maiores no osso D1 e menores no osso D3 (0,84mm e 0,46mm, respetivamente). Em termos de macrogeometria dos implantes, nĂŁo encontramos diferenças nos desvios angulares dos implantes em estudo. Quanto aos desvios obtidos a nĂ­vel do colo, os implantes BLX registaram valores significativamente mais elevados, tridimensionalmente (p=0,001; 0,91 mm), buco-lingual (p=0,02; 0,25mm) e apicocoronal (p=0,032; 0,70mm). Analisados os desvios a nĂ­vel apical, os implantes BLT apresentaram maiores desvios em todos os parĂąmetros, mas com significĂąncia apenas na direção buco-lingual (p=0,045; 0,49mm). ConclusĂŁo: A broca plana melhora a precisĂŁo angular da colocação de implantes em protocolos parcialmente guiados, mantendo nĂ­veis de precisĂŁo linear comparĂĄveis aos procedimentos convencionais. A densidade Ăłssea e a macrogeometria do implante nĂŁo influenciam significativamente os desvios angulares, mas mostram ser variĂĄveis a considerar no planeamento de cirurgia implantar uma vez que podem potenciar desvios tridimensionais e lineares quer a nĂ­vel do colo quer no ĂĄpice do implante.por
dc.description.abstractIntroduction: Partially guided implant surgery aims to increase the clinical accuracy of surgical procedures. The main objective of this study was to evaluate the impact of the milling cutter drill on the spatial accuracy of Bone Level (BL) implant placement within a partially guided surgical protocol. Secondarily, the study aimed to assess the influence of bone density and implant macrogeometry on the primary stability of implants. Materials & Methods: A total of 120 implants (StraumannŸ BL, BLT, and BLX) were placed into homogeneous polyurethane blocks simulating four bone density levels (D13D4). Implant placement was carried out using 3D-printed surgical guides following a partially guided protocol, with or without the use of the milling cutter drill. Deviations between the virtually planned positions on coDiagnostiXŸ software and the final implant positions were evaluated using the "Treatment Evaluation" tool, measuring three-dimensional and angular deviations at the implant's coronal and apical levels. Statistical analysis was performed with the software IBMŸ SPSSŸ Statistics v. 24., with significance set at p<0,05. Results: In a general analysis, the greatest three-dimensional deviations were observed at the apex (0.88mm) compared to the implant neck (0.56mm), in the absence of the milling cutter drill. The use of the milling cutter drill significantly reduced the angular deviation in implant placement (from 3.40° to 2.45°; p=0.007). Regarding bone density, although no significant differences were found in angular deviation, it was higher in D4 bone (3.60°). Significant differences were recorded at the implant neck both three-dimensionally (p=0.027; D3 bone=0.40 mm; D1 bone=0.99 mm) and linearly in the mesio-distal (p=0.036; D2/D3 bone=0.08 mm; D1 bone=0.12mm) and bucco-lingual directions (p<0.001; D3 bone=0.06 mm; D1 bone=0.58 mm). At the implant apex, significant differences were found only for linear deviations in the apico-coronal direction (p=0.005), with higher values in D1 bone and lower values in D3 bone (0.84mm and 0.46mm, respectively). In terms of implant macrogeometry, no differences were observed in angular deviations between the implant types studied. At the implant neck, BLX implants exhibited significantly greater deviations in three-dimensional (p=0.001; 0.91mm), bucco-lingual (p=0.02; 0.25mm), and apico-coronal (p=0.032; 0.70mm) directions. At the apex, BLT implants showed greater deviations in all parameters, although statistical significance was only reached in the bucco-lingual direction (p=0.045; 0.49mm). Conclusions: The milling cutter drill improves the angular accuracy of implant placement in partially guided protocols, while maintaining linear precision levels comparable to conventional procedures. Although bone density and implant macrogeometry do not significantly affect angular deviations, they are important variables to consider in implant surgery planning, as they may influence both three-dimensional and linear deviations at the neck and apex of the implant.eng
dc.identifier.tid203981073
dc.identifier.urihttp://hdl.handle.net/10400.14/54206
dc.language.isopor
dc.rights.uriN/A
dc.subjectImplantes dentĂĄrios
dc.subjectCirurgia assistida por computador
dc.subjectTomografia computorizada de feixe cĂłnico
dc.subjectInformåtica médica dentåria
dc.subjectProstodontia
dc.subjectDental implants
dc.subjectComputer-assisted surgery
dc.subjectCone-beam computed tomography
dc.subjectDental informatics
dc.subjectProsthodontics
dc.titleA influĂȘncia da broca plana em cirurgia de implantes parcialmente guiadapor
dc.typemaster thesis
dspace.entity.typePublication
thesis.degree.nameMestrado em Medicina DentĂĄria

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
203981073.pdf
Size:
848.69 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
3.44 KB
Format:
Item-specific license agreed upon to submission
Description: