Repository logo
 
Publication

Fatigue and microgap behaviour of a three-unit implant-fixed dental prosthesis combining conventional and dynamic abutments

dc.contributor.authorFerreira, José Rocha
dc.contributor.authorSong, Nannan
dc.contributor.authorMachado, Margarida
dc.contributor.authorMachado, Luís
dc.contributor.authorCorreia, André
dc.contributor.authorReis, Ana
dc.date.accessioned2023-09-27T15:24:12Z
dc.date.available2023-09-27T15:24:12Z
dc.date.issued2018-07-04
dc.description.abstractThis is an in vitro study composed by a fatigue test followed by an optical microscopy analysis. Dynamic abutments concept, recently introduced on screw-retained implant dental prosthesis, consists on the screw channel customisation according to the individual needs of each rehabilitation. Geometry and tightening torque differences advise the assessment of their mechanical performance. Clarify whether the combination of dynamic and conventional abutments in a three-unit implant-fixed prosthesis has detrimental effects either on the mechanical performance under cyclic loading or on the implant-abutment microgap dimensions. The fatigue test was performed in agreement with the ISO standard 14801. Then on the samples that resisted 5 million cycles, the implant-abutment microgap was measured on dynamic and conventional abutments using optical microscopy. Two unloaded samples were used as control group. The samples supported a load of 1050 N. The implant-abutment microgap measurement did not show statistically significant differences (p =.086) between loaded and unloaded groups, but the loaded conventional abutments showed a significant lower implant-abutment microgap (p =.05) than the loaded dynamic abutments. The combination of conventional and dynamic abutments do not seem to produce a decrease in fatigue resistance to a level below the mastication forces or an increase in the joint dimensions.pt_PT
dc.description.versioninfo:eu-repo/semantics/acceptedVersionpt_PT
dc.identifier.doi10.1080/03091902.2018.1520312pt_PT
dc.identifier.eid85057316616
dc.identifier.issn0309-1902
dc.identifier.pmid30422735
dc.identifier.urihttp://hdl.handle.net/10400.14/42676
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/pt_PT
dc.subjectDynamic abutmentspt_PT
dc.subjectFatigue testpt_PT
dc.subjectMicrogappt_PT
dc.titleFatigue and microgap behaviour of a three-unit implant-fixed dental prosthesis combining conventional and dynamic abutmentspt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage405pt_PT
oaire.citation.issue5pt_PT
oaire.citation.startPage397pt_PT
oaire.citation.titleJournal of Medical Engineering and Technologypt_PT
oaire.citation.volume42pt_PT
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
20589629.pdf
Size:
977.59 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
3.44 KB
Format:
Item-specific license agreed upon to submission
Description: