Logo do repositório
 
Publicação

Implementação das normas ISO 8196 e 9622 para análise de leite e produtos lácteos

datacite.subject.fosCiências Agrárias::Biotecnologia Agrária e Alimentarpt_PT
dc.contributor.advisorLima, Anabela de
dc.contributor.authorDurães, Mariana Santiago
dc.date.accessioned2023-11-07T16:44:42Z
dc.date.available2024-11-01T01:32:26Z
dc.date.issued2023-07-27
dc.date.submitted2023-07
dc.description.abstractCom o avanço tecnológico e a procura por métodos alternativos, surgiu a necessidade de estabelecer normas para a calibração de equipamentos, garantindo a qualidade das medições ao comparar os valores obtidos com valores de referência aceites. Para abordar a calibração de métodos alternativos, foram desenvolvidas duas normas específicas: a Norma ISO 8196, que se refere a precisão geral dos métodos de análise do leite, e a Norma ISO 9622, que se concentra na aplicação da espectrometria de infravermelho médio em amostras de leite e outros produtos lácteos líquidos. A empresa Lactogal S.A., local do estágio, adotou metodologias baseadas nessas normas para uniformizar e melhorar as calibrações dos seus equipamentos. Para isso, foi desenvolvido um modelo interno para simplificar o processo de calibração, seguindo diretrizes como o número mínimo de amostras, práticas de manipulação, frequência de calibração e critérios de avaliação. Com base nesse modelo, determinou-se cálculos específicos para manipular os componentes desejados. Os critérios de avaliação incluíram coeficiente de correlação, desvio-padrão dos resíduos, declive e diferenças médias. Além disso, foi criado um modelo para analisar a estabilidade do sinal dos equipamentos ao longo do tempo, onde foram identificadas instabilidades que poderiam comprometer os resultados. Foi estabelecida a análise gráfica do controlo realizado e definidas as regras que permitem verificar a conformidade do sistema implementado. A empresa também melhorou os critérios utilizados nos testes interlaboratoriais, que avaliam a precisão e exatidão dos equipamentos em relação aos métodos de referência. Os laboratórios das unidades fabris participaram desses testes, utilizando as diferenças médias entre os valores obtidos e os valores de referência como avaliação. Em conclusão, a implementação das normas foi realizada de acordo com os critérios estabelecidos por elas e foram introduzidas ou melhoradas outras formas de avaliar a precisão e exatidão dos equipamentos.pt_PT
dc.description.abstractWith technological advances and the search for alternative methods, the need has arisen to establish standards for the calibration of equipment, ensuring the quality of measurements by comparing the values obtained with accepted reference values. To address the calibration of alternative methods, two specific standards were developed: ISO 8196, which refers the general accuracy of milk analysis methods, and ISO 9622, which focuses on the application of mid-infrared spectrometry in milk samples and other liquid dairy products. The company Lactogal S.A., internship location, has adopted methodologies based on these standards to standardise and improve the calibrations of its equipment. An internal model was established to simplify the calibration process, following guidelines such as the minimum number of samples, handling practices, calibration frequency and evaluation criteria. Based on this model, specific calculations were determined to manipulate the desired components. The evaluation criteria included correlation coefficient, standard deviation of residuals, slope and mean differences. Furthermore, a model was implemented to analyse the stability of the signal of the equipment over time, identifying possible instabilities that could compromise the results. The analysis of the control chart and the established rules allowed the compliance of the system to be verified. The company also improved the parameters used in the interlaboratory tests, which evaluate the precision and accuracy of the equipment in relation to the reference methods. The laboratories of the manufacturing units participated in these tests, using the average differences between the values obtained and the reference values as an evaluation. In conclusion, the implementation of the standards was carried out according to the criteria established by them. In addition, other ways of evaluating the accuracy and precision of the equipment were introduced or improved.pt_PT
dc.identifier.tid203355237pt_PT
dc.identifier.urihttp://hdl.handle.net/10400.14/42989
dc.language.isoporpt_PT
dc.subjectNormalizaçãopt_PT
dc.subjectCalibraçãopt_PT
dc.subjectProdutos lácteospt_PT
dc.subjectImplementação de métodopt_PT
dc.subjectStandardizationpt_PT
dc.subjectCalibrationpt_PT
dc.subjectDairy productspt_PT
dc.subjectMethod implementationpt_PT
dc.titleImplementação das normas ISO 8196 e 9622 para análise de leite e produtos lácteospt_PT
dc.typemaster thesis
dspace.entity.typePublication
rcaap.rightsopenAccesspt_PT
rcaap.typemasterThesispt_PT
thesis.degree.nameMestrado em Engenharia Alimentarpt_PT

Ficheiros

Principais
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
203355237.pdf
Tamanho:
1.49 MB
Formato:
Adobe Portable Document Format
Licença
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
license.txt
Tamanho:
3.44 KB
Formato:
Item-specific license agreed upon to submission
Descrição: