Repository logo
 
Publication

Exploring portable ultrasonic pulse velocity avails in the conservation assessment of plaster sculptures in museum environment

dc.contributor.authorAlmeida, António Mário
dc.contributor.authorPereira, Mário António
dc.contributor.authorVasconcelos, Graça
dc.contributor.authorCarvalho, Salomé
dc.contributor.authorBordalo, Rui
dc.contributor.authorVieira, Eduarda
dc.date.accessioned2024-04-16T09:28:30Z
dc.date.available2024-04-16T09:28:30Z
dc.date.issued2021
dc.description.abstractUltrasonic pulse velocity (UPV) is generally used in Civil Engineering as an in situ and non-destructive methodology to assess the condition of construction materials. Given the fact that non-contemporary sculpture was traditionally made with similar materials – stone, wood, clay or plaster – a hypothesis arose regarding the possible contribution of UPV for the conservation assessment of sculptures with stone-based materials. Plaster is a fragile material, very susceptible to internal and external fractures, alterations and losses. Museum sculptures cannot be moved to a laboratory, due to conservation protocols and therefore portable UPV could, in theory, play an important role in assessing these artistic structures in situ. There are scarce references to such a methodology, and its implementation implied a partnership with Soares dos Reis National Museum (Porto, Portugal) for an experimental approach to three plaster sculptures made by A. Soares dos Reis: “St. Joseph”, “St. Joachim” (both made in 1880) and “Narcissus” (1881). The aim of this study was to assess if portable UPV could help to detect superficial and internal damages and differences between the original plaster and added materials.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.doi10.34632/ecr.2021.16081pt_PT
dc.identifier.issn1647-2098
dc.identifier.urihttp://hdl.handle.net/10400.14/44599
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/pt_PT
dc.subjectUPVpt_PT
dc.subjectSculpturept_PT
dc.subjectPlasterpt_PT
dc.subjectConservationpt_PT
dc.subjectMuseumpt_PT
dc.subjectSoares dos Reispt_PT
dc.titleExploring portable ultrasonic pulse velocity avails in the conservation assessment of plaster sculptures in museum environmentpt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage59pt_PT
oaire.citation.issue13pt_PT
oaire.citation.startPage42pt_PT
oaire.citation.titleEstudos de Conservação e Restauropt_PT
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
95000518.pdf
Size:
3.11 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
3.44 KB
Format:
Item-specific license agreed upon to submission
Description: