Publication
Development of a chromatographic low pressure flow injection system using amperometric detection: Application to the analysis of niacin in coffee
dc.contributor.author | Santos, João Rodrigo | |
dc.contributor.author | Rangel, António O. S. S. | |
dc.date.accessioned | 2016-01-08T12:01:19Z | |
dc.date.available | 2016-01-08T12:01:19Z | |
dc.date.issued | 2015 | |
dc.description.abstract | In this work, an analytical flow system able to perform low pressure chromatography with amperometric detection is presented. As case study, the determination of niacin (vitamin B3) in coffee brewed samples was selected. The manifold comprised a 1.0 cm length monolithic column coated with didecyldimethylammonium bromide, a laboratory-made boron doped diamond electrode, and featured in-line ionic strength adjustment of the mobile phase. The figures of merit concerning the selected case study namely, detection limit, 7.90 10 7 M, determination rate, ca. 10 samples h 1, mobile phase and ISA solution consumption, ca. 2.6 mL per analysis, and CV, below 5% for retention time and peak height, showed the competitiveness of this analytical strategy comparing to the described HPLC methods for niacin determination. The strategy displays a simple configuration, low cost, fast and easy assembling, foreseeing its use to general purpose applications. | pt_PT |
dc.description.version | info:eu-repo/semantics/publishedVersion | |
dc.identifier.citation | SANTOS, João Rodrigo; RANGEL, António O. S. S. - Development of a chromatographic low pressure flow injection system using amperometric detection: Application to the analysis of niacin in coffee. Food Chemistry. ISSN 0308-8146. N.º 187 (2015), p. 152–158 | pt_PT |
dc.identifier.doi | 10.1016/j.foodchem.2015.04.093 | pt_PT |
dc.identifier.eid | 84928485024 | |
dc.identifier.eissn | 1873-7072 | |
dc.identifier.issn | 0308-8146 | |
dc.identifier.pmid | 25977010 | |
dc.identifier.uri | http://hdl.handle.net/10400.14/18865 | |
dc.identifier.wos | 000355885400021 | |
dc.language.iso | eng | pt_PT |
dc.peerreviewed | yes | pt_PT |
dc.publisher | Elsevier | pt_PT |
dc.relation | Strategic Project - LA 16 - 2011-2012 | |
dc.relation | DESENVOLVIMENTO DE SISTEMAS AUTOMÁTICOS MINIATURIZADOS DE BAIXO CUSTO NA CARACTERIZAÇÃO QUÍMICA DE CAFÉS | |
dc.subject | Low pressure chromatography | pt_PT |
dc.subject | Flow analysis | pt_PT |
dc.subject | Coffee | pt_PT |
dc.subject | Vitamin B3 | pt_PT |
dc.subject | Niacin | pt_PT |
dc.subject | Boron doped diamond electrode | pt_PT |
dc.subject | Modified monolithic columns | pt_PT |
dc.title | Development of a chromatographic low pressure flow injection system using amperometric detection: Application to the analysis of niacin in coffee | pt_PT |
dc.type | journal article | |
dspace.entity.type | Publication | |
oaire.awardTitle | Strategic Project - LA 16 - 2011-2012 | |
oaire.awardTitle | DESENVOLVIMENTO DE SISTEMAS AUTOMÁTICOS MINIATURIZADOS DE BAIXO CUSTO NA CARACTERIZAÇÃO QUÍMICA DE CAFÉS | |
oaire.awardURI | info:eu-repo/grantAgreement/FCT/6817 - DCRRNI ID/PEst-OE%2FEQB%2FLA0016%2F2011/PT | |
oaire.awardURI | info:eu-repo/grantAgreement/FCT//SFRH%2FBPD%2F63492%2F2009/PT | |
oaire.citation.endPage | 158 | |
oaire.citation.startPage | 152 | |
oaire.citation.title | Food Chemistry | |
oaire.citation.volume | 187 | |
oaire.fundingStream | 6817 - DCRRNI ID | |
person.familyName | Santos | |
person.familyName | Santos Silva Rangel | |
person.givenName | João | |
person.givenName | António Osmaro | |
person.identifier.ciencia-id | 2315-DA7D-9221 | |
person.identifier.ciencia-id | D61D-7CFB-178A | |
person.identifier.orcid | 0000-0002-4182-4431 | |
person.identifier.orcid | 0000-0002-6486-8947 | |
person.identifier.rid | D-3198-2012 | |
person.identifier.scopus-author-id | 15763817400 | |
person.identifier.scopus-author-id | 7004827387 | |
project.funder.identifier | http://doi.org/10.13039/501100001871 | |
project.funder.identifier | http://doi.org/10.13039/501100001871 | |
project.funder.name | Fundação para a Ciência e a Tecnologia | |
project.funder.name | Fundação para a Ciência e a Tecnologia | |
rcaap.rights | restrictedAccess | pt_PT |
rcaap.type | article | pt_PT |
relation.isAuthorOfPublication | aabaef19-ecc1-4be4-bba2-5a11228a53be | |
relation.isAuthorOfPublication | 467be022-fd9c-4549-aa48-48ebcc1098eb | |
relation.isAuthorOfPublication.latestForDiscovery | 467be022-fd9c-4549-aa48-48ebcc1098eb | |
relation.isProjectOfPublication | 649dc879-e68a-45df-bcc4-1e66a0521a49 | |
relation.isProjectOfPublication | 15fe8787-765a-40ec-b79a-57189df5775c | |
relation.isProjectOfPublication.latestForDiscovery | 649dc879-e68a-45df-bcc4-1e66a0521a49 |