Publication
The success rate of the adhesive partial fixed prosthesis after five years: a systematic review
| dc.contributor.author | Santos, Maria Catarina | |
| dc.contributor.author | Azevedo, Luis | |
| dc.contributor.author | Fonseca, Patrícia | |
| dc.contributor.author | Viana, Pedro Couto | |
| dc.contributor.author | Araújo, Filipe | |
| dc.contributor.author | Villarinho, Eduardo | |
| dc.contributor.author | Fernandes, Gustavo Vicentis Oliveira | |
| dc.contributor.author | Correia, André | |
| dc.date.accessioned | 2023-04-19T15:48:03Z | |
| dc.date.available | 2023-04-19T15:48:03Z | |
| dc.date.issued | 2023-03-07 | |
| dc.description.abstract | Objective: Evaluation of the success and/or survival rates of resin-bonded fixed partial dentures (RBFPDs) reported in the scientific literature with a minimum average observation time of five years. Materials and Methods: Search conducted in Pubmed, Web of Science, and Cochrane databases in free-text format and MESH terms, until May 2021. The random-effects model was used for the estimated survival rate, percentage per year of estimated failure, and existing complications for the meta-analysis. Study heterogeneity was assessed by the inconsistency test (I2) and study quality by the Downs and Black scale. Results: Eleven articles were included, with 687 participants and 783 RBFPDs, with a mean observation time of 8.2 years, with success rates mentioned in three articles and survival rates reported in nine articles. A total of 142 failures were reported for 783 prostheses, the most frequent being debonding. The estimated failure rate was between 0.53% and 5.10% per year. The studies were of sufficient quality. In the meta-analysis, the survival rates showed a significant result (p < 0.001), with moderate heterogeneity (I2 = 58.76%). Conclusions: Within the limitations of this research, mainly related to the heterogeneity of the studies and their quality, it seems possible to conclude that RBFPDs are a viable clinical option for the rehabilitation of patients with single edentulous spaces, mainly when using a single retainer and a zirconia-ceramic prosthesis. | pt_PT |
| dc.description.version | info:eu-repo/semantics/publishedVersion | pt_PT |
| dc.identifier.doi | 10.3390/prosthesis5010021 | pt_PT |
| dc.identifier.eid | 85151150188 | |
| dc.identifier.issn | 2673-1592 | |
| dc.identifier.uri | http://hdl.handle.net/10400.14/40898 | |
| dc.identifier.wos | 000958342900001 | |
| dc.language.iso | eng | pt_PT |
| dc.peerreviewed | yes | pt_PT |
| dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | pt_PT |
| dc.subject | Maryland bridge | pt_PT |
| dc.subject | Resin-bonded fixed dental prosthesis | pt_PT |
| dc.subject | Resin-bonded fixed partial denture | pt_PT |
| dc.title | The success rate of the adhesive partial fixed prosthesis after five years: a systematic review | pt_PT |
| dc.type | journal article | |
| dspace.entity.type | Publication | |
| oaire.citation.endPage | 294 | pt_PT |
| oaire.citation.issue | 1 | pt_PT |
| oaire.citation.startPage | 282 | pt_PT |
| oaire.citation.title | Prosthesis | pt_PT |
| oaire.citation.volume | 5 | pt_PT |
| rcaap.rights | openAccess | pt_PT |
| rcaap.type | article | pt_PT |
