Repository logo
 
Publication

Transporte e armazenamento : garantia de esterilidade dos dispositivos médicos críticos

datacite.subject.fosCiências Médicas::Ciências da Saúde
dc.contributor.advisorRocha, Pedro Miguel de Mendonça
dc.contributor.advisorCapelas, Manuel Luís Vila
dc.contributor.authorRodrigues, Ana Maria Amaral
dc.date.accessioned2015-05-26T15:36:07Z
dc.date.available2015-05-26T15:36:07Z
dc.date.issued2014-07-07
dc.date.submitted2013
dc.description.abstractIntrodução: O reprocessamento dos dispositivos médicos críticos (DMc) visa a ausência de microrganismos viáveis de modo a garantir a segurança do doente, o qual incorpora a limpeza/desinfeção, inspeção, empacotamento, esterilização, armazenamento, transporte e uso. Trata-se de um processo que exige condições físicas adequadas, normalização, monitorização, formação e supervisão. No ciclo de reprocessamento de DMc todas as fases são vitais, convergindo para a prevenção de infeções associadas aos cuidados de saúde. A presente investigação teve como objetivos: determinar a carga microbiana dos DMc e analisar a garantia da esterilidade após transporte e armazenamento num Agrupamento dos Centros de Saúde (ACES). Material e Métodos: No procedimento metodológico foram usados DMc novos habitualmente utilizados nas salas de tratamento, que após esterilização foram transportados até ao serviço utilizador em contentor de material não poroso, facilmente lavável, rígido e hermético. Posteriormente foram armazenados durante 21 dias consecutivos em gavetas sem climatização ambiente e analisada a garantia de esterilidade através de ensaios bioquímicos de resíduos de proteínas, ensaios de ATP bioluminescência e ensaios microbiológicos. Resultados: Os resultados evidenciaram que a carga bacteriana presente nos DMc após transporte e armazenamento num ACES é nula, dado que: não se verificou turvação do inóculo nem crescimento de UFC nos meios de cultura, os valores quantificados de ATP são nulos e não se detetou proteína residual. Conclusões: Estes resultados, dão-nos boas indicações da esterilidade dos DMc.por
dc.description.abstractIntroduction: The reprocessing of critical medical devices (DMc) aims the absence of viable microorganisms in order to ensure patient safety, which incorporates cleaning/ disinfection, inspection, packaging, sterilization, storage, transportation and use. It is a process that requires adequate physical conditions, standardization, monitoring, training and supervision. In DMc reprocessing cycle all phases are vital, converging to the prevention of health care associated infections. The present investigation had as objectives: to determine the DMc microbial load and analyze the assurance of sterility after transportation and storage in a Group of Health Centers (ACES). Material and Methods: New DMc commonly used in treatment rooms were employed in the methodological procedure that after being sterilized were moved in containers of non-porous material, easily washable, hard and airtight. Later they were stored for 21 days in drawers without cooling environment. The assurance of sterility was analyzed through biochemical assays of protein, ATP bioluminescence assays and microbiological assays. Results: The results showed that the bacterial load in DMc after transportation and storage in an ACES is null because there was no turbidity of the inoculum nor growth of the UFC in the culture media, the quantified ATP values were null and no residual protein was detected. Conclusion: This results give us good indication of DMc sterilitypor
dc.identifier.tid201679566
dc.identifier.urihttp://hdl.handle.net/10400.14/17747
dc.language.isoporpor
dc.subjectReprocessamentopor
dc.subjectEsterilizaçãopor
dc.subjectATP bioluminescênciapor
dc.subjectResíduos de proteínaspor
dc.subjectEnsaios microbiológicospor
dc.subjectReprocessingpor
dc.subjectSterilizationpor
dc.subjectATP bioluminescencepor
dc.subjectProtein residuespor
dc.subjectMicrobiological assaypor
dc.titleTransporte e armazenamento : garantia de esterilidade dos dispositivos médicos críticospor
dc.typemaster thesis
dspace.entity.typePublication
rcaap.rightsopenAccesspor
rcaap.typemasterThesispor
thesis.degree.nameMestrado em Infeção em Cuidados de Saúde

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
201679566.pdf
Size:
1.66 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
3.44 KB
Format:
Item-specific license agreed upon to submission
Description: