Repository logo
 
Publication

Factors that interfere with the response of nurses in the monitoring of clinical alarms

dc.contributor.authorDinis, Sónia Margarida Meireles
dc.contributor.authorRabiais, Isabel Cristina Mascarenhas
dc.date.accessioned2021-04-30T09:33:30Z
dc.date.available2021-04-30T09:33:30Z
dc.date.issued2017-01-01
dc.description.abstractObjective:: The objective of the present study was to identify and synthesize the best empirical evidence found on factors that influence the response of nurses regarding clinical alarms. Method:: An integrative literature review was conducted with searches undertaken in ten electronic databases restricted to the period from 2005 to 2016. Results:: Eight articles were included by cross-checking the descriptors selected. Conclusion:: In the analysis of the studies, the following possible factors that might interfere with the response of nurses in the monitoring of clinical alarms were found: high number of false alarms, inaudibility of alarms due to the competition of sounds, difficulty in distinguishing the urgency of alarms, and increase in noise caused by the raise in the number of alarms.pt_PT
dc.description.abstractO presente estudo tem como propósito refletir sobre a prática de enfermagem no que concerne à temática da monitorização dos alarmes clínicos. Objetivo: Pretendemos identificar e sintetizar, a melhor, a evidência empírica produzida sobre os fatores que influenciam a resposta dos enfermeiros perante os alarmes clínicos. Método: Perspetivou-se um estudo de revisão integrativa da literatura. Selecionámos um conjunto de dez bases de dados eletrónicas, delimitou-se a pesquisa ao período temporal de 2005 a 2016. Resultados: Por meio de uma estratégia de cruzamento dos descritores selecionados, foram incluídos oito artigos. Conclusão: Na análise dos estudos, reconhecemos como possíveis fatores que interferem na resposta dos enfermeiros na monitorização dos alarmes clínicos: o grande número de falsos alarmes, a inaudibilidade dos alarmes por causa da competição de sons, a dificuldade de distinguir a urgência dos alarmes e o aumento do ruído provocado pelo aumento do número de alarmes.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.doi10.1590/0034-7167-2015-0092pt_PT
dc.identifier.eid85037567574
dc.identifier.issn0034-7167
dc.identifier.pmid28226057
dc.identifier.urihttp://hdl.handle.net/10400.14/32848
dc.identifier.wos000404282300022
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/pt_PT
dc.subjectClinical alarmspt_PT
dc.subjectNoisept_PT
dc.subjectNursingpt_PT
dc.subjectProfessional competencept_PT
dc.subjectSafetypt_PT
dc.subjectAlarmes clínicospt_PT
dc.subjectRuídopt_PT
dc.subjectEnfermagempt_PT
dc.subjectCompetência profissionalpt_PT
dc.subjectSegurançapt_PT
dc.titleFactors that interfere with the response of nurses in the monitoring of clinical alarmspt_PT
dc.title.alternativeFatores que interferem na resposta dos enfermeiros na monitorização dos alarmes clínicospt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage179pt_PT
oaire.citation.issue1pt_PT
oaire.citation.startPage172pt_PT
oaire.citation.titleRevista brasileira de enfermagempt_PT
oaire.citation.volume70pt_PT
person.familyNameRabiais
person.givenNameIsabel
person.identifier.ciencia-idCD19-43C8-339F
person.identifier.orcid0000-0002-8342-1171
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublication349ee344-da55-4d79-ba29-796c1923da22
relation.isAuthorOfPublication.latestForDiscovery349ee344-da55-4d79-ba29-796c1923da22

Files

Original bundle
Now showing 1 - 2 of 2
No Thumbnail Available
Name:
26780217_en.pdf
Size:
590.73 KB
Format:
Adobe Portable Document Format
Description:
Inglês
No Thumbnail Available
Name:
26780217_pt.pdf
Size:
596.62 KB
Format:
Adobe Portable Document Format
Description:
Português