Browsing by Author "Ribeiro, Susana O."
Now showing 1 - 2 of 2
Results Per Page
Sort Options
- Iron determination in natural waters using a synthesised 3-hydroxy-4-pyridione ligand in a newly developed microfluidic paper-based devicePublication . Aguiar, Juliana I. S.; Ribeiro, Susana O.; Leite, Andreia; Rangel, Maria; Rangel, António O. S. S.; Mesquita, Raquel B. R.This work describes the development of an iron sensor based on a microfluidic paper-based technique, to attain iron quantification in natural waters. A new water-soluble naphthalene-3-hydroxy-4-pyridione ligand was used as a colour reagent, as it formed an orange complex with iron. As a newly described ligand, several chemical and physical parameters, namely, the sample and reagent volumes and reagent concentrations, were studied related to the formation of the coloured complex. The microfluidic paper-based analytical device (μPAD) assembly, namely, the use of different types of filter paper and different numbers of layers, was developed to obtain the best performance. Under the optimal conditions, a linear correlation was obtained in the range of 0.25–2.00 mg/L of iron, with a minimum detectable value of 0.07 mg/L. The proposed μPAD method was validated by an analysis of the certified samples and by a comparison of the tested water samples with the inductively coupled plasma (ICP) results (RE < 10%). Then, the μPAD device was successfully applied to the determination of iron in tap water, well water, river water, and seawater, with no need for any prior sample pre-treatment; recovery studies were also performed (average = 100.3% with RSD = 4.2%).
- Use of a rhodamine-based chelator in a microfluidic paper-based analytical device for the in-situ copper quantification in natural watersPublication . Aguiar, Juliana I. S.; Ribeiro, Susana O.; Leite, Andreia; Rangel, Maria; Rangel, António O. S. S.; Mesquita, Raquel B. R.This work describes the development of a microfluidic paper-based analytical device (μPAD) for the determination of copper in fresh and marine waters. A functionalized rhodamine-based chelator was synthesized and used as a chromogenic reagent, forming a highly intense pink complex with the analyte. The aim was to create a paper device that offers optimal performance and provides in-situ, rapid and cost-effective analysis in line with World Health Organization guidelines. The influence on the determination of several physical and chemical parameters was evaluated aiming to achieve the best performance. Under optimised conditions, a linear correlation was established in the range of 0.05–0.50 mg L−1 of copper, with a limit of detection of 10 μg L−1. The accuracy of the proposed method was assessed by comparing the results obtained with the developed μPAD and the results obtained with Inductively Coupled Plasma measurements (RE < 10 %). Recovery studies were also performed using different types of water samples with no need for any prior sample pre-treatment: tap, well, river and seawater. The average recovery percentage of 101 % (RSD = 4.3 %) was obtained, a clear indication of no multiplicative matrix interferences.