Critical evaluation of restrictions used to optimize sterilization processing conditions

Use this identifier to reference this record.

Advisor(s)

Abstract(s)

A computer program, using a finite differences method, was developed to model the heat sterilization for cylindrical packaged conduction heating foods. This program was introduced into an optimization routineto calculate optimum processing conditions, maximizing the surface or the volume average quality, using different restrictions. Depending on the pack dimensions and the heating rate of the product the least-lethality point is at the geometric center or along the radius or the vertical axis. Therefore, sterility values specified at the center and at the least-Iethality point were used as sterility criteria for calculating optimum conditions. The effect of an integrated sterility value constraint on optimal temperature was also investigated. Depending on the product thermal properties, processing conditions and target lethality the optimum temperature calculated using the sterility value at the center as restriction can overestimate the correet valueby as much as 4°C.

Description

Keywords

Pedagogical Context

Citation

SILVA, C. L. M. ; KORCZAK, K. - Critical evaluation of restrictions used to optimize sterilization processing conditions. In Bath Food Process Engineering Conference, 4, Bath, UK, 19-21 September, 1994 - 4th Bath Food Process Engineering Conference : Book of Abstracts. [S.l. : s.n., 1994]. 8 p.