Interfacing multisyringe flow injection analysis to flame atomic emission spectrometry: an intelligent system for automatic sample dilution and determination of potassium

dc.contributor.authorAlmeida, M. Inês G. S.
dc.contributor.authorSegundo, Marcela A.
dc.contributor.authorLima, José L. F. C.
dc.contributor.authorRangel, António O. S. S.
dc.date.accessioned2010-09-30T15:40:26Z
dc.date.available2010-09-30T15:40:26Z
dc.date.issued2009
dc.description.abstractInterfacing automatic flow systems to atomic emission/absorption spectrometry based on flame atomisation techniques may present some difficulties, especially when there are flow interruptions inherent to the technique of automation applied. Therefore, in the present work, different configurations for interfacing multisyringe flow injection analysis (MSFIA) systems to flame-based detectors (flame emission spectrometer in this case) are proposed and compared. To illustrate the feasibility of the selected approach, an intelligent flow system was implemented for in-line dilution of samples prior to determination of potassium content. By selecting the injection volume and the number of dilution channels activated, a dynamic concentration range (1–2000 mg L 1) was established, allowing direct introduction of soil extracts (1–20 mg L 1), parenteral solutions (20–600 mg L 1) and table wines (200–2000 mg L 1). The sampling frequency (three replicates per sample) was about 14 h 1.por
dc.description.versioninfo:eu-repo/semantics/publishedVersion
dc.identifier.citation"Journal of Analytical Atomic Spectrometry". ISSN 0267-9477. 24 (2009) 340–346por
dc.identifier.doi10.1039/b813150c
dc.identifier.urihttp://hdl.handle.net/10400.14/2646
dc.language.isoengpor
dc.publisherRoyal Society of Chemistrypor
dc.titleInterfacing multisyringe flow injection analysis to flame atomic emission spectrometry: an intelligent system for automatic sample dilution and determination of potassiumpor
dc.typejournal article
dspace.entity.typePublication
person.familyNameGameiro de Sa Almeida
person.familyNameSegundo
person.familyNameLima
person.familyNameSantos Silva Rangel
person.givenNameMaria Ines
person.givenNameMarcela
person.givenNameJosé
person.givenNameAntónio Osmaro
person.identifierR-000-8FJ
person.identifier.ciencia-id0A14-B7A6-E805
person.identifier.ciencia-id4811-9AA9-D673
person.identifier.ciencia-idD61D-7CFB-178A
person.identifier.orcid0000-0002-5272-3468
person.identifier.orcid0000-0003-2938-0214
person.identifier.orcid0000-0002-8906-9826
person.identifier.orcid0000-0002-6486-8947
person.identifier.ridA-1009-2010
person.identifier.scopus-author-id6602384941
person.identifier.scopus-author-id10141079100
person.identifier.scopus-author-id7004827387
rcaap.rightsrestrictedAccesspor
rcaap.typearticlepor
relation.isAuthorOfPublicationa0e0a8f4-578a-4359-a6d2-8626e155ac83
relation.isAuthorOfPublication84c05a53-23fa-4f4b-b007-d1a5fc748d5a
relation.isAuthorOfPublication71f20aa3-d4ae-40c3-a9ef-27d88442d1e0
relation.isAuthorOfPublication467be022-fd9c-4549-aa48-48ebcc1098eb
relation.isAuthorOfPublication.latestForDiscovery71f20aa3-d4ae-40c3-a9ef-27d88442d1e0

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Interfacing multisyringe flow injection.pdf
Size:
188.12 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: