Repository logo
 
Publication

Clinical analysis of the influence of surface roughness in the primary stability and osseointegration of dental implants: study in humans

dc.contributor.authorBrum, Igor da Silva
dc.contributor.authorElias, Carlos Nelson
dc.contributor.authorLopes, João Carlos Amorim
dc.contributor.authorFrigo, Lucio
dc.contributor.authorSantos, Paulo Gonçalo Pinto dos
dc.contributor.authorCarvalho, Jorge José de
dc.date.accessioned2024-09-18T10:46:05Z
dc.date.available2024-09-18T10:46:05Z
dc.date.issued2024-08
dc.description.abstractIn past decades, the success rates of the first dental implant treatments were low (75%). Nowadays, oral rehabilitation with titanium dental implants has a high success rate (95%–98%). The success rate significantly increases due to increased scientific knowledge about osseointegration, changes in surgical techniques, and the development of implant surface treatments. Despite the high success rate of implants, there are no protocols to define the time for the prosthesis to be installed, the insertion torque, and the prosthesis loaded after surgery. This work compares a new dental implant’s primary (mechanical) and secondary (osseointegration) stability. Dental implants with micro- and nano-roughness surfaces were placed in 24 patients with a minimum of 35 N·cm and a maximum of 60 N·cm. Primary stability was quantified with a torque wrench and an Ostell Mentor Device. The secondary stability 45 and 60 days after surgery was measured with Ostell. The results showed no statistical difference in secondary stability at 45 and 60 days postoperatively among implants. The success rate of dental implants can be associated with the surface morphology with micro- and nano-roughness, the insertion torque value, and the shape of the implant threads. When the manufacturer’s guidelines are followed, it is possible to prosthetically rehabilitate the patient with an implant 45 days after surgery.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.doi10.3390/coatings14080951pt_PT
dc.identifier.eid85202690425
dc.identifier.issn2079-6412
dc.identifier.urihttp://hdl.handle.net/10400.14/46578
dc.identifier.wos001305108300001
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/pt_PT
dc.subjectDental implantpt_PT
dc.subjectEdentulouspt_PT
dc.subjectOsseointegrationpt_PT
dc.subjectPrimary stabilitypt_PT
dc.subjectSecondary stabilitypt_PT
dc.titleClinical analysis of the influence of surface roughness in the primary stability and osseointegration of dental implants: study in humanspt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.issue8pt_PT
oaire.citation.titleCoatingspt_PT
oaire.citation.volume14pt_PT
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
105170064.pdf
Size:
11.26 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
3.44 KB
Format:
Item-specific license agreed upon to submission
Description: