Publicação
Deep-learning denoising for ultrahigh-resolution photon-counting detector CT: phantom and in vivo evaluation of non-calcified coronary plaques
| dc.contributor.author | Hyska, Sardi | |
| dc.contributor.author | Hagar, Muhammad Taha | |
| dc.contributor.author | Osoria-Velasquez, José | |
| dc.contributor.author | Fink, Nicola | |
| dc.contributor.author | Ricke, Jens | |
| dc.contributor.author | Halfmann, Moritz C. | |
| dc.contributor.author | Marques, Hugo | |
| dc.contributor.author | McVeigh, Elliot | |
| dc.contributor.author | Wesbey, George | |
| dc.contributor.author | Maurovich-Horvat, Pál | |
| dc.contributor.author | Szilveszter, Bálint | |
| dc.contributor.author | Emrich, Tilman | |
| dc.contributor.author | Varga-Szemes, Akos | |
| dc.contributor.author | Vecsey-Nagy, Milan | |
| dc.date.accessioned | 2026-07-17T16:07:32Z | |
| dc.date.available | 2026-07-17T16:07:32Z | |
| dc.date.issued | 2026-07-10 | |
| dc.description.abstract | To assess the value of convolutional neural network (CNN)-based denoising for the evaluation of non-calcified coronary plaques on ultrahigh-resolution (UHR) photon-counting detector (PCD) coronary CT angiography (CCTA). A dynamic phantom containing lipid-rich and fibrotic plaques with 50%-diameter stenosis (PDS) was scanned on PCD-CT under varying conditions. For in-vivo imaging, consecutive patients with non-calcified coronary plaques (NCPs) who underwent CCTA with PCD-CT were included. Image series were reconstructed using a sharp vascular kernel (Bv64) with slice thicknesses of 0.2 mm/0.4 mm, quantum iterative reconstruction (QIR) levels 3/4, and with/without CNN denoising. Phantom-based line-profile analysis yielded edge-width at half maximum (EWHM) and 10–90% rise distance as sharpness metrics. Plaque contrast-to-noise ratio (CNR) and PDS were assessed in the phantom and in patients. Two readers evaluated subjective image quality (noise, diagnostic confidence) using a four-point Likert scale. Pairwise comparisons were performed using a Bonferroni-corrected p < 0.002 for significance. Fifty-five patients (median age 74 [66.5–78] years; 19 women) with 97 NCPs were included. Phantom-based sharpness metrics remained unchanged after denoising (all pairwise p > 0.051). CNN denoising increased plaque CNR consistently in the phantom (fibrotic: 0.80–1.64 to 0.92–2.06; lipid-rich: 0.21–0.34 to 0.35–0.46) and in vivo (0.99–2.07 to 1.37–2.92, all pairwise p < 0.001). Denoising did not alter PDS values in phantom or in vivo plaques (all pairwise p > 0.006). Subjective image noise and diagnostic confidence improved across all reconstructions (all pairwise p < 0.001). CNN-based denoising of UHR PCD-CT improves image quality of non-calcified coronary plaques, while preserving sharpness and quantitative stenosis metrics. | eng |
| dc.identifier.doi | 10.1007/s10554-026-03774-x | |
| dc.identifier.eid | 105044359482 | |
| dc.identifier.other | 52d107bc-c983-4cdb-ad50-2891c23cc901 | |
| dc.identifier.pmid | 42430068 | |
| dc.identifier.uri | http://hdl.handle.net/10400.14/58751 | |
| dc.identifier.wos | 001817364500001 | |
| dc.language.iso | eng | |
| dc.peerreviewed | yes | |
| dc.publisher | Springer Science and Business Media B.V. | |
| dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | |
| dc.subject | Coronary artery disease | eng |
| dc.subject | Coronary computed tomography angiography | eng |
| dc.subject | Non-calcified plaque | eng |
| dc.subject | Photon-counting detector | eng |
| dc.subject | Ultrahigh-resolution | eng |
| dc.title | Deep-learning denoising for ultrahigh-resolution photon-counting detector CT: phantom and in vivo evaluation of non-calcified coronary plaques | |
| dc.type | research article | |
| dspace.entity.type | Publication | |
| oaire.version | http://purl.org/coar/version/c_ab4af688f83e57aa |
Ficheiros
Principais
1 - 1 de 1
