Publication
Improved methods for the enumeration of heterotrophic bacteria in bottled mineral waters
| dc.contributor.author | Ramalho, Rita | |
| dc.contributor.author | Cunha, Joaquim | |
| dc.contributor.author | Teixeira, Paula | |
| dc.contributor.author | Gibbs, Paul A. | |
| dc.date.accessioned | 2011-10-22T16:25:24Z | |
| dc.date.available | 2011-10-22T16:25:24Z | |
| dc.date.issued | 2001 | |
| dc.description.abstract | At this time the European Union regulations require that the heterotrophic plate counts (HPC) of mineral waters be assessed at two recovery temperatures: 22°C for 72 h and 37°C for 24 h. This procedure is time consuming and expensive. Development of new rapid methods for microbiological assessment of the microbial flora in the bottled water is an industry-driven need. The objectives of this work were to develop a method for the HPC that utilises only one recovery temperature and one incubation period and evaluate the use of, the LIVE/DEAD® BacLight™ Bacterial Viability Kit, 5-cyano-2,3-ditotyl tetrazolium chloride (CTC) and impedance methods to enumerate viable bacteria in bottled mineral water. Results showed that incubation at 30°C could be used instead of incubation at 22°C and 37°C. Good correlation exists between counts at 30°C and counts at 22°C (r>0.90) and all the pathogens important in mineral water analyses grow similarly at 30°C and 37°C during 24 h. It was demonstrated that impedance methods might be useful to the mineral water industry as a rapid indicator of microbiological quality of the water. Results obtained with BacLight and CTC were similar to those obtained with plate counts. | por |
| dc.identifier.citation | RAMALHO, Rita ...[et al.] - Improved methods for the enumeration of heterotrophic bacteria in bottled mineral waters. Journal of Microbiological Methods. ISSN 0167-7012. Vol. 44, n.º2 (2001), p. 97–103 | por |
| dc.identifier.uri | http://hdl.handle.net/10400.14/6841 | |
| dc.language.iso | eng | por |
| dc.peerreviewed | yes | por |
| dc.publisher | Elsevier | por |
| dc.relation.publisherversion | doi:10.1016/S0167-7012(00)00237-2 | por |
| dc.subject | BacLight | por |
| dc.subject | CTC | por |
| dc.subject | Heterotrophic plate counts | por |
| dc.subject | Impedance methods | por |
| dc.subject | Mineral water | por |
| dc.title | Improved methods for the enumeration of heterotrophic bacteria in bottled mineral waters | por |
| dc.type | journal article | |
| dspace.entity.type | Publication | |
| person.familyName | Teixeira | |
| person.familyName | Gibbs | |
| person.givenName | Paula | |
| person.givenName | Paul | |
| person.identifier.orcid | 0000-0002-6296-5137 | |
| person.identifier.orcid | 0000-0002-6580-4363 | |
| person.identifier.rid | J-8678-2014 | |
| person.identifier.scopus-author-id | 7005895206 | |
| rcaap.rights | openAccess | por |
| rcaap.type | article | por |
| relation.isAuthorOfPublication | b918d4a2-b9f9-4c56-8318-111625e4d58b | |
| relation.isAuthorOfPublication | 218d85c8-40f4-42c0-9a47-4e8ad9f72a96 | |
| relation.isAuthorOfPublication.latestForDiscovery | 218d85c8-40f4-42c0-9a47-4e8ad9f72a96 |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- Improved methods for the enumeration of heterotrophic bacteria in bottled mineral waters.PDF
- Size:
- 141.82 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 3.44 KB
- Format:
- Item-specific license agreed upon to submission
- Description:
