Use of flow injection multisite detection as a novel approach for blank signal correction in a spectrophotometric determination

dc.contributor.authorOliveira, Teresa A.C.
dc.contributor.authorMesquita, Raquel B. R.
dc.contributor.authorLima, José L. F. C.
dc.contributor.authorRangel, António O. S. S.
dc.date.accessioned2011-10-21T16:35:26Z
dc.date.available2011-10-21T16:35:26Z
dc.date.issued2005
dc.description.abstractA flow injection multisite detection system was developed for correction of the sample blank in a colorimetric determination. By using detector relocation, a single spectrophotometer is used for the sequential reading of the sample blank and of the colored product; the sample crosses the flow cell to measure intrinsic absorption, the color reagent is subsequently added, and the flow cell is relocated to provide the reading of the resulting plug. The subsequent detector relocation immediately after peak maximum increases the determination frequency. This strategy was tested in the colorimetric determination of iron in soil samples based on the reaction of Fe (II) with 1,10-phenanthroline after reduction of Fe (III) to Fe (II) by ascorbic acid. The results obtained for 15 soil extracts were in good agreement with those obtained by the reference procedure. Relative standard deviations better than 4% were obtained, with a sampling rate of 30/h.por
dc.description.versioninfo:eu-repo/semantics/publishedVersion
dc.identifier.citation"Journal of AOAC International" . ISSN 1060-3271. 88:5 (2005) 1511-1515por
dc.identifier.doi10.1093/jaoac/88.5.1511
dc.identifier.urihttp://hdl.handle.net/10400.14/6745
dc.language.isoengpor
dc.peerreviewedyespor
dc.titleUse of flow injection multisite detection as a novel approach for blank signal correction in a spectrophotometric determinationpor
dc.typejournal article
dspace.entity.typePublication
person.familyNameMesquita
person.familyNameLima
person.familyNameSantos Silva Rangel
person.givenNameRaquel
person.givenNameJosé
person.givenNameAntónio Osmaro
person.identifierJ-4630-2013
person.identifierR-000-8FJ
person.identifier.ciencia-idEB1D-DEE3-0B60
person.identifier.ciencia-id4811-9AA9-D673
person.identifier.ciencia-idD61D-7CFB-178A
person.identifier.orcid0000-0001-7745-1860
person.identifier.orcid0000-0002-8906-9826
person.identifier.orcid0000-0002-6486-8947
person.identifier.ridJ-4630-2013
person.identifier.scopus-author-id7005556626
person.identifier.scopus-author-id10141079100
person.identifier.scopus-author-id7004827387
rcaap.rightsrestrictedAccesspor
rcaap.typearticlepor
relation.isAuthorOfPublicationf89887f1-4d1b-438b-8f03-27d9bda1de7b
relation.isAuthorOfPublication71f20aa3-d4ae-40c3-a9ef-27d88442d1e0
relation.isAuthorOfPublication467be022-fd9c-4549-aa48-48ebcc1098eb
relation.isAuthorOfPublication.latestForDiscovery467be022-fd9c-4549-aa48-48ebcc1098eb

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Use of flow injection.pdf
Size:
87.07 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
3.44 KB
Format:
Item-specific license agreed upon to submission
Description: