Logo do repositório
 
Publicação

A double-line sequential injection system for the spectrophotometric determination of copper, iron, manganese, and zinc in waters

dc.contributor.authorMorais, Inês P. A.
dc.contributor.authorSouto, M. Renata S.
dc.contributor.authorRangel, António O. S. S.
dc.date.accessioned2011-10-18T16:52:11Z
dc.date.available2011-10-18T16:52:11Z
dc.date.issued2005
dc.description.abstractA double-line sequential injection system was developed for the spectrophotometric determination of several metal ions in waters. The proposed double-line configuration was used to enable adding sample and chromogenic reagents as merging zones. The methodology was applied to the spectrophotometric determination of copper, iron, manganese, and zinc in samples of diverse origins at the range of 0.15–5.00, 0.10–10.0, 0.48–4.00, and 0.11–5.00 mg/L, respectively. Different chromogenic reagents and detection wavelengths were used. The chromogenic reagents for iron and manganese were 1,10-phenanthroline and formaldoxime, respectively. Copper and zinc were both determined using the analytical reagent zincon. Analytical characteristics of the methodology, such as manifold parameters, buffer pH, and reagent concentrations were optimized, and interference of some of the metal ions commonly present in water sample was assessed. Results of the analysis were in agreement with those obtained by atomic absorption spectrometry. Repeatability, expressed as the relative standard deviation for 10 consecutive injections of water samples, was lower than 6%. The determination rate was approximately 36/h.por
dc.identifier.citationMORAIS, Inês P. A. ; SOUTO, M. Renata S. ; RANGEL - A double-line sequential injection system for the spectrophotometric determination of copper, iron, manganese, and zinc in waters. Journal of AOAC International. ISSN 1060-3271. Vol. 88, n.º 2 (2005), p. 639-344por
dc.identifier.urihttp://hdl.handle.net/10400.14/6433
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherAOAC Internationalpor
dc.titleA double-line sequential injection system for the spectrophotometric determination of copper, iron, manganese, and zinc in waterspor
dc.typejournal article
dspace.entity.typePublication
person.familyNameSantos Silva Rangel
person.givenNameAntónio Osmaro
person.identifier.ciencia-idD61D-7CFB-178A
person.identifier.orcid0000-0002-6486-8947
person.identifier.scopus-author-id7004827387
rcaap.rightsrestrictedAccesspor
rcaap.typearticlepor
relation.isAuthorOfPublication467be022-fd9c-4549-aa48-48ebcc1098eb
relation.isAuthorOfPublication.latestForDiscovery467be022-fd9c-4549-aa48-48ebcc1098eb

Ficheiros

Principais
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
art_int_arb_2005_ESB_1022_Rangel_António_256.pdf
Tamanho:
107.71 KB
Formato:
Adobe Portable Document Format
Licença
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
license.txt
Tamanho:
3.44 KB
Formato:
Item-specific license agreed upon to submission
Descrição: