Repository logo
 
Publication

A multi-syringe flow injection system for the spectrophotometric determination of trace levels of iron in waters using a liquid waveguide capillary cell and different chelating resins and reaction chemistries

dc.contributor.authorPáscoa, Ricardo N. M. J.
dc.contributor.authorTóth, Ildikó V.
dc.contributor.authorRangel, António O. S. S.
dc.date.accessioned2010-11-05T11:24:59Z
dc.date.available2010-11-05T11:24:59Z
dc.date.issued2009
dc.description.abstractA method integrating a long waveguide capillary cell with a preconcentration resin in a multi-syringe flow injection analysis (MSFIA) system for iron determination in waters was developed. The determination of iron is based on a colorimetric reaction and two reagents were tested, ferrozine and ammonium thiocyanate. A liquid waveguide capillary cell (1.0 m pathlength, 550 μm i.d. and 250 μL internal volume) with a preconcentration resin were used to improve the sensitivity of the determination. Two different preconcentration resins were also tested, Chelex 100 and NTA Superflow. The developed method employing the NTA Superflow with ferrozine colorimetric reagent provided a detection limit of 0.05 μg L−1 with a linear response up to 8 μg L−1 and a sample throughput rate of 12 per hour. The developed system presents low reagents/sample consumptions. The accuracy was assessed using a certified reference water sample.por
dc.description.versioninfo:eu-repo/semantics/publishedVersion
dc.identifier.citationPÁSCOA ,Ricardo N. M. J. ; TÓTH, Ildikó V. ; RANGEL, António O.S.S. - A multi-syringe flow injection system for the spectrophotometric determination of trace levels of iron in waters using a liquid waveguide capillary cell and different chelating resins and reaction chemistries. Microchemical Journal. ISSN 0026-265X. Vol. 93, n.º 2 (2009), p. 153–158por
dc.identifier.doi10.1016/j.microc.2009.06.003
dc.identifier.urihttp://hdl.handle.net/10400.14/3312
dc.language.isoengpor
dc.publisherElsevierpor
dc.subjectIronpor
dc.subjectMulti-syringe flow injection analysispor
dc.subjectLiquid waveguide capillary celpor
dc.subjectPre-concentration resinspor
dc.subjectSpectrophotometrypor
dc.titleA multi-syringe flow injection system for the spectrophotometric determination of trace levels of iron in waters using a liquid waveguide capillary cell and different chelating resins and reaction chemistriespor
dc.typejournal article
dspace.entity.typePublication
person.familyNamePáscoa
person.familyNameTóth
person.familyNameSantos Silva Rangel
person.givenNameRicardo
person.givenNameIldikó
person.givenNameAntónio Osmaro
person.identifier.ciencia-idBA14-0549-AA0A
person.identifier.ciencia-idD61D-7CFB-178A
person.identifier.orcid0000-0003-2073-7643
person.identifier.orcid0000-0002-7342-1063
person.identifier.orcid0000-0002-6486-8947
person.identifier.ridD-4791-2013
person.identifier.ridG-1733-2010
person.identifier.scopus-author-id11738933900
person.identifier.scopus-author-id35512332800
person.identifier.scopus-author-id7004827387
rcaap.rightsrestrictedAccesspor
rcaap.typearticlepor
relation.isAuthorOfPublication2140ed4c-4229-4ff5-9940-c7b476f09741
relation.isAuthorOfPublication7889563f-f3fc-4057-a97c-b51425b4dc46
relation.isAuthorOfPublication467be022-fd9c-4549-aa48-48ebcc1098eb
relation.isAuthorOfPublication.latestForDiscovery7889563f-f3fc-4057-a97c-b51425b4dc46

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
1-s2.0-S0026265X09000861-main.pdf
Size:
178.81 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
3.44 KB
Format:
Item-specific license agreed upon to submission
Description: