Repository logo
 
Publication

Automated solid-phase spectrophotometric system for optosensing of bromate in drinking waters

dc.contributor.authorOliveira, Sara M.
dc.contributor.authorOliveira, Hugo M.
dc.contributor.authorSegundo, Marcela A.
dc.contributor.authorRangel, António O. S. S.
dc.contributor.authorLima, José L. F. C.
dc.contributor.authorCerdà, Vıctor
dc.date.accessioned2013-01-28T13:38:20Z
dc.date.available2013-01-28T13:38:20Z
dc.date.issued2012
dc.description.abstractAn automated method based on an optosensor included in a multisyringe flow injection system was developed for the determination of bromate in waters for human consumption. The optosensor was based on the formation of a colored radical cation after oxidation of chlorpromazine by bromate and its selective uptake in a mixed-mode cation exchanger sorbent (Discovery DSC-MCAX), placed on a flow-through spectrophotometric cell. In-line regeneration was attained by methanol + 5% (v/v) ammonia, fostering the application of the same sorbent portion up to 180 determinations. Parameters affecting the reaction development and uptake of the colored compound were studied and optimized, while in-line addition of sulfite ($0.100 g L 1) prevented interference from hypochlorite. The proposed methodology allowed the determination of bromate up to 50.0 mg L 1, with 0.9 mg L 1 as the limit of detection, meeting the requirements of current EU and USA legislation. Application to real drinking water samples was successful, with a mean recovery of 100.2 2.8% for spiked levels of 5.0, 10.0 and 25.0 mg L 1. Repeatability was good (RSD < 3.6%, n ¼ 10) with a determination throughput of 8 h 1, fostering the application to on-line control of water disinfection processes.por
dc.description.versioninfo:eu-repo/semantics/publishedVersion
dc.identifier.citationOLIVEIRA, Sara M...[et al.] - Automated solid-phase spectrophotometric system for optosensing of bromate in drinking waters. Analytical Methods. ISSN 1759-9679. Vol. 4, n.º 5 (2012), p. 1229-1236por
dc.identifier.doi10.1039/c2ay05860j
dc.identifier.eissn1759-9679
dc.identifier.issn1759-9660
dc.identifier.urihttp://hdl.handle.net/10400.14/9989
dc.identifier.wosWOS:000303603000007
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherRoyal Society of Chemistrypor
dc.relationStrategic Project - LA 6 - 2011-2012
dc.titleAutomated solid-phase spectrophotometric system for optosensing of bromate in drinking waterspor
dc.typejournal article
dspace.entity.typePublication
oaire.awardTitleStrategic Project - LA 6 - 2011-2012
oaire.awardURIinfo:eu-repo/grantAgreement/FCT/6820 - DCRRNI ID/PEst-C%2FEQB%2FLA0006%2F2011/PT
oaire.awardURIinfo:eu-repo/grantAgreement/FCT/SFRH/SFRH%2FBD%2F23782%2F2005/PT
oaire.citation.endPage1236
oaire.citation.issue5
oaire.citation.startPage1229
oaire.citation.startPage4
oaire.citation.titleAnalytical Methods
oaire.fundingStream6820 - DCRRNI ID
oaire.fundingStreamSFRH
person.familyNameOliveira
person.familyNameOliveira
person.familyNameSegundo
person.familyNameSantos Silva Rangel
person.familyNameLima
person.familyNameCerdà
person.givenNameSara
person.givenNameHugo M.
person.givenNameMarcela
person.givenNameAntónio Osmaro
person.givenNameJosé
person.givenNameVíctor
person.identifier353413
person.identifierR-000-8FJ
person.identifier.ciencia-id901F-2504-CC7A
person.identifier.ciencia-id0A14-B7A6-E805
person.identifier.ciencia-idD61D-7CFB-178A
person.identifier.ciencia-id4811-9AA9-D673
person.identifier.orcid0000-0003-0649-2694
person.identifier.orcid0000-0002-9023-2563
person.identifier.orcid0000-0003-2938-0214
person.identifier.orcid0000-0002-6486-8947
person.identifier.orcid0000-0002-8906-9826
person.identifier.orcid0000-0001-7474-9426
person.identifier.ridM-5180-2013
person.identifier.ridG-1445-2010
person.identifier.ridA-1009-2010
person.identifier.scopus-author-id16022986400
person.identifier.scopus-author-id8433457900
person.identifier.scopus-author-id6602384941
person.identifier.scopus-author-id7004827387
person.identifier.scopus-author-id10141079100
person.identifier.scopus-author-id7005344678
project.funder.identifierhttp://doi.org/10.13039/501100001871
project.funder.identifierhttp://doi.org/10.13039/501100001871
project.funder.nameFundação para a Ciência e a Tecnologia
project.funder.nameFundação para a Ciência e a Tecnologia
rcaap.rightsrestrictedAccesspor
rcaap.typearticlepor
relation.isAuthorOfPublication6663c3d3-4fe7-4fe6-a175-8f9e1f76d978
relation.isAuthorOfPublication644138cf-a0bb-4c06-83db-c0be181ec005
relation.isAuthorOfPublication84c05a53-23fa-4f4b-b007-d1a5fc748d5a
relation.isAuthorOfPublication467be022-fd9c-4549-aa48-48ebcc1098eb
relation.isAuthorOfPublication71f20aa3-d4ae-40c3-a9ef-27d88442d1e0
relation.isAuthorOfPublication3e3a8fb0-abb9-4f13-bcdb-b2ae6d783829
relation.isAuthorOfPublication.latestForDiscovery467be022-fd9c-4549-aa48-48ebcc1098eb
relation.isProjectOfPublicationeebc3e2e-4e79-4c9b-a190-a926db4ab8bc
relation.isProjectOfPublicationf36a7a4e-8109-44c2-847e-1a6597912149
relation.isProjectOfPublication.latestForDiscoveryeebc3e2e-4e79-4c9b-a190-a926db4ab8bc

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
AI16.pdf
Size:
249.07 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
3.44 KB
Format:
Item-specific license agreed upon to submission
Description: