Publication
Cathodic voltammetric detection of diltiazem at a bismuth film electrode: application to human urine and pharmaceuticals
dc.contributor.author | Catarino, Rita I. L. | |
dc.contributor.author | Leal, M. Fernanda C. | |
dc.contributor.author | Pimenta, Adriana M. | |
dc.contributor.author | Souto, M. Renata S. | |
dc.contributor.author | Lopes, Joana R. T. | |
dc.date.accessioned | 2021-09-08T16:43:47Z | |
dc.date.available | 2021-09-08T16:43:47Z | |
dc.date.issued | 2014-05 | |
dc.description.abstract | In this work it was developed a novel application of bismuth film electrodes (BiFEs) for the determination of the antihypertensive and coronary vasodilator diltiazem by square wave cathodic voltammetry. The bismuth film was deposited ex situ on a glassy carbon electrode for 90 s at -1.4 V vs. Ag/AgCl, from an acetate buffer (pH 4.5; 0.10 mol L-1) containing 5 or 30 mg L -1 Bi. Diltiazem analytical signal was obtained in phosphate buffer (pH 7.4; 0.25 mol L-1) where reduction takes place at -1.5 V vs. Ag/AgCl. The proposed methodology was applied to the quantification of diltiazem in pharmaceutical samples (dynamic linear range comprised between 90 and 900 μg L-1) and in human urine (dynamic linear range comprised between 45 and 270 μg L-1, and detection limit of 12 μg L -1). | pt_PT |
dc.description.abstract | Neste trabalho foi desenvolvida uma nova metodologia de voltametria catódica de onda quadrada com elétrodo de filme de bismuto (BiFE) para a determinação de um anti-hipertensivo e vasodilatador coronário – o diltiazem. O filme de bismuto foi depositado ex situ na superfície de um elétrodo de carbono vítreo durante 90 s a um potencial de –1,4 V vs. Ag/AgCl, usando uma solução de tampão acetato (pH 4,5; 0,10 mol L-1) contendo 5 ou 30 mg L-1 de Bi. O sinal analítico do diltiazem foi obtido numa solução de tampão fostato (pH 7,4; 0,25 mol L-1) onde se verificou que a redução ocorria a –1,5 V vs. Ag/AgCl. A metodologia proposta foi aplicada à quantificação de diltiazem em formulações farmacêuticas (faixa linear de resposta compreendida entre 90 e 900 µg L-1) e em amostras de urina (faixa linear de resposta compreendida entre 45 e 270 µg L-1, e limite de deteção de 12 µg L-1). | pt_PT |
dc.description.version | info:eu-repo/semantics/publishedVersion | pt_PT |
dc.identifier.doi | 10.5935/0103-5053.20140067 | pt_PT |
dc.identifier.eid | 84902346566 | |
dc.identifier.issn | 0103-5053 | |
dc.identifier.uri | http://hdl.handle.net/10400.14/34698 | |
dc.identifier.wos | 000335817400020 | |
dc.language.iso | eng | pt_PT |
dc.peerreviewed | yes | pt_PT |
dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0/ | pt_PT |
dc.subject | Bismuth film electrode | pt_PT |
dc.subject | Diltiazem | pt_PT |
dc.subject | Pharmaceuticals | pt_PT |
dc.subject | Voltammetry | pt_PT |
dc.title | Cathodic voltammetric detection of diltiazem at a bismuth film electrode: application to human urine and pharmaceuticals | pt_PT |
dc.type | journal article | |
dspace.entity.type | Publication | |
oaire.citation.endPage | 968 | pt_PT |
oaire.citation.issue | 5 | pt_PT |
oaire.citation.startPage | 961 | pt_PT |
oaire.citation.title | Journal of the Brazilian Chemical Society | pt_PT |
oaire.citation.volume | 25 | pt_PT |
person.familyName | Catarino | |
person.familyName | Leal | |
person.familyName | Pimenta | |
person.familyName | Souto | |
person.givenName | Rita | |
person.givenName | Fernanda | |
person.givenName | Adriana | |
person.givenName | Renata | |
person.identifier.ciencia-id | B517-2F1F-F2E4 | |
person.identifier.ciencia-id | 5916-B87F-2482 | |
person.identifier.ciencia-id | 211D-C53A-B059 | |
person.identifier.ciencia-id | 9814-DF91-15FA | |
person.identifier.orcid | 0000-0001-9010-2921 | |
person.identifier.orcid | 0000-0002-0118-9007 | |
person.identifier.orcid | 0000-0003-1975-5094 | |
person.identifier.orcid | 0000-0002-2130-8667 | |
person.identifier.rid | D-6597-2013 | |
person.identifier.rid | D-6188-2013 | |
person.identifier.rid | D-6248-2013 | |
person.identifier.rid | M-7017-2013 | |
person.identifier.scopus-author-id | 6603283442 | |
person.identifier.scopus-author-id | 7101675251 | |
person.identifier.scopus-author-id | 36841737900 | |
person.identifier.scopus-author-id | 7005270435 | |
rcaap.rights | openAccess | pt_PT |
rcaap.type | article | pt_PT |
relation.isAuthorOfPublication | 52bc8ba6-62fe-4201-a3d3-929eb63f3b3d | |
relation.isAuthorOfPublication | 3bcd8da3-960c-442f-9fb7-2e680c369a28 | |
relation.isAuthorOfPublication | 49440195-c1d1-47ff-8c91-5f9c7e49f08e | |
relation.isAuthorOfPublication | 796cdb44-719b-4e76-b6aa-d6c5472409e4 | |
relation.isAuthorOfPublication.latestForDiscovery | 796cdb44-719b-4e76-b6aa-d6c5472409e4 |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- a20v25n5.pdf
- Size:
- 281.59 KB
- Format:
- Adobe Portable Document Format