Logo do repositório
 
Publicação

Exploiting the bead injection LOV approach to carry out spectrophotometric assays in wine: application to the determination of iron

dc.contributor.authorVidigal, Susana S. M. P.
dc.contributor.authorTóth, Ildikó V.
dc.contributor.authorRangel, António O. S. S.
dc.date.accessioned2012-01-12T12:12:39Z
dc.date.available2012-01-12T12:12:39Z
dc.date.issued2011
dc.description.abstractA sequential injection lab-on-valve (SI-LOV) system was used to develop a new methodology for the determination of iron in wine samples exploiting the bead injection (BI) concept for solid phase extraction and spectrophotometric measurement. Nitrilotriacetic Acid (NTA) Superflow resin was used to build the bead column of the flow through sensor. The iron (III) ions were retained by the bead column and react with SCN- producing an intense red colour. The change in absorbance was monitored spectrophotometrically on the optosensor at 480 nm. It was possible to achieve a linear range of 0.09-5.0 mg L-1 of iron, with low sample and reagent consumption; 500 mu L of sample, 15 mu mol of SCN-, and 9 mu mol of H2O2, per assay. The proposed method was successfully applied to the determination of iron in wine, with no previous treatment other than dilution, and to other food samples.por
dc.description.versioninfo:eu-repo/semantics/publishedVersion
dc.identifier.citationVIDIGAL, Susana S. M. P.; TÓTH, Ildikó V.; RANGEL, António O. S. S. - Exploiting the bead injection LOV approach to carry out spectrophotometric assays in wine: application to the determination of iron. In International Conference on Flow Injection Analysis and Related Techniques,16th,(ICFIA 2010), Pattaya, Tailândia, 25-30 Abril, 2010. Talanta. ISSN 0039-9140. Vol. 84, n.º 5 (2011), p. 1298-1303por
dc.identifier.doi10.1016/j.talanta.2011.01.041
dc.identifier.eissn1873-3573
dc.identifier.issn0039-9140
dc.identifier.urihttp://hdl.handle.net/10400.14/7430
dc.identifier.wosWOS:000292475600017
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherElsevierpor
dc.subjectSolid phase spectrometrypor
dc.subjectSequential injection lab-on-valvepor
dc.subjectBead injectionpor
dc.subjectIronpor
dc.subjectWinepor
dc.titleExploiting the bead injection LOV approach to carry out spectrophotometric assays in wine: application to the determination of ironpor
dc.typeconference object
dspace.entity.typePublication
oaire.citation.endPage1303
oaire.citation.issue5
oaire.citation.startPage1298
oaire.citation.titleTalanta
oaire.citation.volume84
person.familyNameVidigal
person.familyNameTóth
person.familyNameSantos Silva Rangel
person.givenNameSusana
person.givenNameIldikó
person.givenNameAntónio Osmaro
person.identifier.ciencia-id2919-B77C-11C0
person.identifier.ciencia-idD61D-7CFB-178A
person.identifier.orcid0000-0002-0213-063X
person.identifier.orcid0000-0002-7342-1063
person.identifier.orcid0000-0002-6486-8947
person.identifier.ridM-4661-2013
person.identifier.ridG-1733-2010
person.identifier.scopus-author-id11739488200
person.identifier.scopus-author-id35512332800
person.identifier.scopus-author-id7004827387
rcaap.rightsrestrictedAccesspor
rcaap.typeconferenceObjectpor
relation.isAuthorOfPublication59453cc2-ee50-4a1d-bbfc-924ca6417004
relation.isAuthorOfPublication7889563f-f3fc-4057-a97c-b51425b4dc46
relation.isAuthorOfPublication467be022-fd9c-4549-aa48-48ebcc1098eb
relation.isAuthorOfPublication.latestForDiscovery467be022-fd9c-4549-aa48-48ebcc1098eb

Ficheiros

Principais
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
1-s2.0-S0039914011000750-main.pdf
Tamanho:
240.94 KB
Formato:
Adobe Portable Document Format
Licença
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
license.txt
Tamanho:
3.44 KB
Formato:
Item-specific license agreed upon to submission
Descrição: