Publication
Determination of aluminum (III) in crystallized fruit samples using a multicommutated flow system
dc.contributor.author | Tóth, Ildikó V. | |
dc.contributor.author | Rangel, António O. S. S. | |
dc.contributor.author | Santos, João L. M. | |
dc.contributor.author | Lima, José L. F. C. | |
dc.date.accessioned | 2011-10-22T10:02:29Z | |
dc.date.available | 2011-10-22T10:02:29Z | |
dc.date.issued | 2004-06 | |
dc.description.abstract | A multicommutated flow system was developed for the determination of aluminum in crystallized fruit samples. Spectrophotometric determination is based on the reaction of aluminum with chrome azurol S. The binary sampling technique was implemented to improve mixing conditions and to minimize reagent consumption. Three different working zones were established (0.5-5.0, 5.0-25.0, and 10.0-100 ppm) using the zone sampling approach, allowing us to adapt the extent of the in-line dilution. The influence of the chemical and physical parameters on the performance of the system was studied. Detection limits of 0.1, 0.6, and 0.8 ppm were obtained for the lowest, the medium, and the highest dispersion system, respectively. The procedure was applied to the determination of aluminum in crystallized fruit extracts. The results were in agreement with those obtained by the reference flame atomic absorption procedure at a 95% confidence level. Repeatability (RSD) was better than 2.4% in all of the three application zones. | por |
dc.description.version | info:eu-repo/semantics/publishedVersion | |
dc.identifier.citation | "Journal of Agricultural and Food Chemistry" . ISSN 0021-8561. 52: 9 (2004) 2450-2454 | por |
dc.identifier.doi | 10.1021/jf049812v | |
dc.identifier.uri | http://hdl.handle.net/10400.14/6771 | |
dc.language.iso | eng | por |
dc.peerreviewed | yes | por |
dc.publisher | American Chemical Society | por |
dc.subject | Multicommutation | por |
dc.subject | Zone sampling | por |
dc.subject | Aluminum(III) | por |
dc.subject | Crystallized fruits | por |
dc.subject | Spectrophotometry | por |
dc.title | Determination of aluminum (III) in crystallized fruit samples using a multicommutated flow system | por |
dc.type | journal article | |
dspace.entity.type | Publication | |
person.familyName | Tóth | |
person.familyName | Santos Silva Rangel | |
person.familyName | Lima | |
person.givenName | Ildikó | |
person.givenName | António Osmaro | |
person.givenName | José | |
person.identifier | R-000-8FJ | |
person.identifier.ciencia-id | D61D-7CFB-178A | |
person.identifier.ciencia-id | 4811-9AA9-D673 | |
person.identifier.orcid | 0000-0002-7342-1063 | |
person.identifier.orcid | 0000-0002-6486-8947 | |
person.identifier.orcid | 0000-0002-8906-9826 | |
person.identifier.rid | G-1733-2010 | |
person.identifier.scopus-author-id | 35512332800 | |
person.identifier.scopus-author-id | 7004827387 | |
person.identifier.scopus-author-id | 10141079100 | |
rcaap.rights | restrictedAccess | por |
rcaap.type | article | por |
relation.isAuthorOfPublication | 7889563f-f3fc-4057-a97c-b51425b4dc46 | |
relation.isAuthorOfPublication | 467be022-fd9c-4549-aa48-48ebcc1098eb | |
relation.isAuthorOfPublication | 71f20aa3-d4ae-40c3-a9ef-27d88442d1e0 | |
relation.isAuthorOfPublication.latestForDiscovery | 467be022-fd9c-4549-aa48-48ebcc1098eb |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- Determination of aluminium (III) in crystallized fruit samples using a multicommunated flow system.pdf
- Size:
- 67.24 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 3.44 KB
- Format:
- Item-specific license agreed upon to submission
- Description: