Repository logo
 
Publication

New computational solution to compute the uptake index from 99m Tc-MDP bone scintigraphy images

dc.contributor.authorAraújo, Vânia
dc.contributor.authorFaria, Diogo
dc.contributor.authorTavares, João Manuel R. S.
dc.date.accessioned2020-03-12T18:23:07Z
dc.date.available2020-03-12T18:23:07Z
dc.date.issued2019
dc.description.abstractThe appearance of bone metastasis in patients with breast or prostate cancer makes the skeleton most affected by metastatic cancer. It is estimated that these two cancers lead in 80% of the cases to the appearance of bone metastasis, which is considered the main cause of death. 99mTc-methylene diphosphonate (99mTc-MDP) bone scintigraphy is the most commonly used radionuclide imaging technique for the detection and prognosis of bone carcinoma. With this work, it was intended to develop a new computational solution to extract from 99mTc-MDP bone scintigraphy images quantitative measurements of the affected regions in relation to the non-pathological regions. Hence, the uptake indexes computed from a new imaging exam are compared with the indexes computed from a previous exam of the same patient. Using active shape models, it is possible to segment the regions of the skeleton more prone to be affected by the bone carcinoma. On the other hand, the metastasis is segmented using the region-growing algorithm. Then, the uptake rate is calculated from the relation between the maximum intensity pixel of the metastatic region in relation to the maximum intensity pixel of the skeletal region where the metastasis was located. We evaluated the developed solution using scintigraphic images of 15 patients (7 females and 8 males) with bone carcinoma in two distinct time exams. The bone scans were obtained approximately 3 h after the injection of 740 MBq of 99mTc-MDP. The obtained indexes were compared against the evaluations in the clinical reports of the patients. It was possible to verify that the indexes obtained are according to the clinical evaluations of the 30 exams analyzed. However, there were 2 cases where the clinical evaluation was unclear as to the progression or regression of the disease, and when comparing the indexes, it is suggested the progression of the disease in one case and the regression in the other one. Based on the obtained results, it is possible to conclude that the computed indexes allow a quantitative analysis to evaluate the response to the prescribed therapy. Thus, the developed solution is promising to be used as a tool to help the technicians at the time of clinical evaluation.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationAraújo, V., Faria, D., Tavares, J. M. R. (2019). New computational solution to compute the uptake index from 99m Tc-MDP bone scintigraphy images. In J.M.R.S. Tavares, P.R. Fernandes (eds.), New Developments on Computational Methods and Imaging in Biomechanics and Biomedical Engineering, Vol.33. (pp. 149-160). Springer, Champt_PT
dc.identifier.doi10.1007/978-3-030-23073-9_10pt_PT
dc.identifier.isbn9783030230739
dc.identifier.urihttp://hdl.handle.net/10400.14/29917
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherSpringerpt_PT
dc.subjectMedical imagingpt_PT
dc.subjectImage segmentationpt_PT
dc.subjectPoint distribution modelpt_PT
dc.subjectActive shape modelpt_PT
dc.subjectBone metastasispt_PT
dc.titleNew computational solution to compute the uptake index from 99m Tc-MDP bone scintigraphy imagespt_PT
dc.typebook part
dspace.entity.typePublication
oaire.citation.endPage160pt_PT
oaire.citation.startPage149pt_PT
oaire.citation.titleNew Developments on Computational Methods and Imaging in Biomechanics and Biomedical Engineeringpt_PT
oaire.citation.volume33pt_PT
person.familyNameTavares
person.givenNameJoão
person.identifier120048
person.identifier.ciencia-id0417-CE76-F7B3
person.identifier.orcid0000-0001-7603-6526
person.identifier.ridM-5305-2013
person.identifier.scopus-author-id36538110300
rcaap.rightsrestrictedAccesspt_PT
rcaap.typebookPartpt_PT
relation.isAuthorOfPublicationeb872e00-d008-4ad7-a5d3-da771bb09ec8
relation.isAuthorOfPublication.latestForDiscoveryeb872e00-d008-4ad7-a5d3-da771bb09ec8

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
20196778.pdf
Size:
1.26 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
3.44 KB
Format:
Item-specific license agreed upon to submission
Description: