Logo do repositório
 
Publicação

Flow-through solid-phase based optical sensor for the multisyringe flow injection trace determination of orthophosphate in waters with chemiluminescence detection

dc.contributor.authorMorais, Inês P.A.
dc.contributor.authorMiró, Manuel
dc.contributor.authorManera, Matias
dc.contributor.authorEstela, José Manuel
dc.contributor.authorCerdà, Víctor
dc.contributor.authorSouto, M. Renata S.
dc.contributor.authorRangel, António O.S.S.
dc.date.accessioned2010-11-18T12:37:03Z
dc.date.available2010-11-18T12:37:03Z
dc.date.issued2004
dc.description.abstractIn this work, a novel flow-through solid-phase based chemiluminescence (CL) optical sensor is described for the trace determination of orthophosphate in waters exploiting the multisyringe flow injection analysis (MSFIA) concept with multicommutation. The proposed time-based injection flow system relies upon the in-line derivatisation of the analyte with ammonium molybdate in the presence of vanadate, and the transient immobilisation of the resulting heteropolyacid in a N-vinylpyrrolidone/divinylbenzene copolymer packed spiral shape flow-through cell located in front of the window of a photomultiplier tube. The simultaneous injection of well-defined slugs of luminol in alkaline medium and methanol solution towards the packed reactor is afterwards performed by proper switching of the solenoid valves. Then, the light emission from the luminol oxidation by the oxidant species retained onto the sorbent material is readily detected. At the same time, the generated molybdenum-blue compound is eluted by the minute amount of injected methanol, rendering the system prepared for a new measuring cycle. Therefore, the devised sensor enables the integration of the solid-phase CL reaction with elution and detection of the emitted light without the typical drawbacks of the molybdenum-blue based spectrophotometric procedures regarding the excess of molybdate anion, which causes high background signals due to its self-reduction. The noteworthy features of the developed CL–MSFIA system are the feasibility to accommodate reactions with different pH requirements and the ability to determine trace levels of orthophosphate in high silicate content samples (Si/P ratios up to 500). Under the optimised conditions, a dynamic linear range from 5 to 50 g P l−1 for a 1.8 ml sample, repeatability better than 3.0% and a quantification limit of 4 g P l−1 were attained. The flowing stream system handles 11 analysis h−1 and has been successfully applied to the determination of trace levels of orthophosphate in environmental samples such as mineral, ground, tap and pond waters as well as samples from a water-steam cycle of an incineration plant. The t-test comparison of the means for the developed optical sensor and the molybdenum-blue spectrophotometric APHA/AWWA/WPCF reference method revealed that there is no evidence of significant differences between the obtained results at the 95% confidence level.por
dc.description.versioninfo:eu-repo/semantics/publishedVersion
dc.identifier.citationMORAIS, Inês A. P...[et al.] - Flow-through solid-phase based optical sensor for the multisyringe flow injection trace determination of orthophosphate in waters with chemiluminescence detection. Anlytica Chimica Acta. ISSN 0003-2670. Vol. 506, n.º 1 (2004), p. 17-24por
dc.identifier.doi10.1016/j.aca.2003.11.020
dc.identifier.urihttp://hdl.handle.net/10400.14/3488
dc.language.isoengpor
dc.publisherElsevierpor
dc.subjectMultisyringe flow injection analysispor
dc.subjectSolid-phase optical sensorpor
dc.subjectChemiluminescencepor
dc.subjectOrthophosphate determinationpor
dc.subjectWaterspor
dc.titleFlow-through solid-phase based optical sensor for the multisyringe flow injection trace determination of orthophosphate in waters with chemiluminescence detectionpor
dc.typejournal article
dspace.entity.typePublication
person.familyNameCerdà
person.familyNameSantos Silva Rangel
person.givenNameVíctor
person.givenNameAntónio Osmaro
person.identifier.ciencia-idD61D-7CFB-178A
person.identifier.orcid0000-0001-7474-9426
person.identifier.orcid0000-0002-6486-8947
person.identifier.scopus-author-id7005344678
person.identifier.scopus-author-id7004827387
rcaap.rightsrestrictedAccesspor
rcaap.typearticlepor
relation.isAuthorOfPublication3e3a8fb0-abb9-4f13-bcdb-b2ae6d783829
relation.isAuthorOfPublication467be022-fd9c-4549-aa48-48ebcc1098eb
relation.isAuthorOfPublication.latestForDiscovery467be022-fd9c-4549-aa48-48ebcc1098eb

Ficheiros

Principais
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
1-s2.0-S0003267003014892-main.pdf
Tamanho:
108.77 KB
Formato:
Adobe Portable Document Format
Licença
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
license.txt
Tamanho:
3.44 KB
Formato:
Item-specific license agreed upon to submission
Descrição: