Repository logo
 
Publication

Potentiometric determination of chloride in vegetables by flow injection analysis

dc.contributor.authorLima, José L. F. C.
dc.contributor.authorRangel, António O. S. S.
dc.contributor.authorSouto, M. Renata S.
dc.date.accessioned2011-10-07T16:25:40Z
dc.date.available2011-10-07T16:25:40Z
dc.date.issued1996
dc.description.abstractA flow injection system for the potentiometric determination of chloride (Cl) in vegetables is reported. A tubular chloride ion-selective electrode based on a homogeneous crystalline membrane without inner reference solution was used as indicator electrode. A methodology to minimize the influence of the sample matrix on the electrodes response is described. The results obtained with the developed flow injection manifold are in good agreement with those provided by the reference method and present good precision (relative standard deviations lower than 2%). Sample throughput ranges from 150 to 300 determinations per hourpor
dc.description.versioninfo:eu-repo/semantics/publishedVersion
dc.identifier.citationLIMA, José L. F. C. ; RANGEL, António O. S. S. SOUTO, M. Renata S. - Potentiometric determination of chloride in vegetables by flow injection analysis. Communications in Soil Science and Plant Analysis. ISSN 0010-3624. 27:1-2 (1996) 37-46por
dc.identifier.doi10.1080/00103629609369542
dc.identifier.urihttp://hdl.handle.net/10400.14/5872
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherTaylor & Francispor
dc.titlePotentiometric determination of chloride in vegetables by flow injection analysispor
dc.typejournal article
dspace.entity.typePublication
person.familyNameLima
person.familyNameSantos Silva Rangel
person.givenNameJosé
person.givenNameAntónio Osmaro
person.identifierR-000-8FJ
person.identifier.ciencia-id4811-9AA9-D673
person.identifier.ciencia-idD61D-7CFB-178A
person.identifier.orcid0000-0002-8906-9826
person.identifier.orcid0000-0002-6486-8947
person.identifier.scopus-author-id10141079100
person.identifier.scopus-author-id7004827387
rcaap.rightsrestrictedAccesspor
rcaap.typearticlepor
relation.isAuthorOfPublication71f20aa3-d4ae-40c3-a9ef-27d88442d1e0
relation.isAuthorOfPublication467be022-fd9c-4549-aa48-48ebcc1098eb
relation.isAuthorOfPublication.latestForDiscovery467be022-fd9c-4549-aa48-48ebcc1098eb

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Potentiometric_determination_of_chloride....pdf
Size:
1.38 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
3.44 KB
Format:
Item-specific license agreed upon to submission
Description: