Publication
Spectrophotometric determination of Bromate in water using multisyringe flow injection analysis
dc.contributor.author | Oliveira, Sara M. | |
dc.contributor.author | Segundo, Marcela A. | |
dc.contributor.author | Rangel, António O. S. S. | |
dc.contributor.author | Lima, José L. F. C. | |
dc.contributor.author | Cerdà, Víctor | |
dc.date.accessioned | 2012-01-12T17:16:12Z | |
dc.date.available | 2012-01-12T17:16:12Z | |
dc.date.issued | 2011 | |
dc.description.abstract | A multisyringe flow injection system for the spectrophotometric determination of bromate in water is proposed, based on the oxidation of phenothiazine compounds by bromate in acidic medium. Several phenothiazines were tested, including chlorpromazine, trifluoperazine, and thioridazine. Higher sensitivity and lower LOD were attained for chlorpromazine. Interference from nitrite, hypochlorite, and chlorite was eliminated in-line, without any changes in the manifold. The automatic methodology using chlorpromazine allowed the determination of bromate between 25 and 750 lgL 1, with LOD of 6 lgL 1, good precision (RSD<1.6%, n¼10), and determination frequency of 35 h 1. | por |
dc.description.version | info:eu-repo/semantics/publishedVersion | |
dc.description.version | 10.1080/00032719.2010.500771 | |
dc.identifier.citation | OLIVEIRA, Sara M....[et al] - Spectrophotometric determination of Bromate in water using multisyringe flow injection analysis. Analytical Letters. ISSN 0003-2719. Vol. 44 (2011), p.84–297 | por |
dc.identifier.uri | http://hdl.handle.net/10400.14/7461 | |
dc.language.iso | eng | por |
dc.peerreviewed | yes | por |
dc.publisher | Taylor & Francis | por |
dc.subject | Bromate | por |
dc.subject | Multisyringe flow injection analysis | por |
dc.subject | Phenothiazines | por |
dc.subject | Spectrophotometry | por |
dc.subject | Water | por |
dc.title | Spectrophotometric determination of Bromate in water using multisyringe flow injection analysis | por |
dc.type | journal article | |
dspace.entity.type | Publication | |
person.familyName | Oliveira | |
person.familyName | Segundo | |
person.familyName | Santos Silva Rangel | |
person.familyName | Lima | |
person.familyName | Cerdà | |
person.givenName | Sara | |
person.givenName | Marcela | |
person.givenName | António Osmaro | |
person.givenName | José | |
person.givenName | Víctor | |
person.identifier | R-000-8FJ | |
person.identifier.ciencia-id | 0A14-B7A6-E805 | |
person.identifier.ciencia-id | D61D-7CFB-178A | |
person.identifier.ciencia-id | 4811-9AA9-D673 | |
person.identifier.orcid | 0000-0003-0649-2694 | |
person.identifier.orcid | 0000-0003-2938-0214 | |
person.identifier.orcid | 0000-0002-6486-8947 | |
person.identifier.orcid | 0000-0002-8906-9826 | |
person.identifier.orcid | 0000-0001-7474-9426 | |
person.identifier.rid | M-5180-2013 | |
person.identifier.rid | A-1009-2010 | |
person.identifier.scopus-author-id | 16022986400 | |
person.identifier.scopus-author-id | 6602384941 | |
person.identifier.scopus-author-id | 7004827387 | |
person.identifier.scopus-author-id | 10141079100 | |
person.identifier.scopus-author-id | 7005344678 | |
rcaap.rights | restrictedAccess | por |
rcaap.type | article | por |
relation.isAuthorOfPublication | 6663c3d3-4fe7-4fe6-a175-8f9e1f76d978 | |
relation.isAuthorOfPublication | 84c05a53-23fa-4f4b-b007-d1a5fc748d5a | |
relation.isAuthorOfPublication | 467be022-fd9c-4549-aa48-48ebcc1098eb | |
relation.isAuthorOfPublication | 71f20aa3-d4ae-40c3-a9ef-27d88442d1e0 | |
relation.isAuthorOfPublication | 3e3a8fb0-abb9-4f13-bcdb-b2ae6d783829 | |
relation.isAuthorOfPublication.latestForDiscovery | 6663c3d3-4fe7-4fe6-a175-8f9e1f76d978 |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- Spectrophotometric Determination of Bromate in Water Using Multisyringe Flow Injection Analysis.pdf
- Size:
- 505.06 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 3.44 KB
- Format:
- Item-specific license agreed upon to submission
- Description: