Repository logo
 
Publication

Construction and use of a tubular picrate ion-selective electrode for reducing sugar determination in Port wine by flow-injection analysis

dc.contributor.authorLopes, Teresa I. M. S.
dc.contributor.authorRangel, António O. S. S.
dc.contributor.authorLima, José L. F. C.
dc.contributor.authorMontenegro, M. Conceição B. S. M.
dc.date.accessioned2011-10-11T11:16:52Z
dc.date.available2011-10-11T11:16:52Z
dc.date.issued1995
dc.description.abstractA picrate ion-selective electrode without inner reference solution and based on bis(triphenylphosphoranylidene)ammonium picrate dissolved in 2-nitrophenyloctyl ether was constructed and its characteristics assessed. With respect to reducing sugar determination in Port wine, a tubular electrode based on the same sensor system was developed and incorporated into a flow-injection manifold devised for this determination. The methodology involves a reaction between the reducing sugar and picric acid, the decrease in the picrate concentration being monitored with the tubular electrode. A linear dependence between peak width, at a fixed potential and the logarithm of sugar concentration in the range 25–200 g l−1 was obtained. The proposed system allows wine samples to be injected with no previous treatment and allows a sample throughput of 50 determinations per hour, a relative standard deviation less than 4%, and the results are comparable to the reference procedures.por
dc.description.versioninfo:eu-repo/semantics/publishedVersion
dc.identifier.citationLOPES, Teresa I. M. S....[et al] - Construction and use of a tubular picrate ion-selective electrode for reducing sugar determination in Port wine by flow-injection analysis. Analytica Chimica Acta. ISSN 0003.2670. Vol. 308 n.º 1-3 (1995), p.122-128por
dc.identifier.doi10.1016/0003-2670(94)00598-G
dc.identifier.eid0029060315
dc.identifier.urihttp://hdl.handle.net/10400.14/5941
dc.identifier.wosA1995RD48900014
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherElsevierpor
dc.subjectFlow injectionpor
dc.subjectIon selective electrodespor
dc.subjectPicratepor
dc.subjectSugarpor
dc.subjectWinepor
dc.titleConstruction and use of a tubular picrate ion-selective electrode for reducing sugar determination in Port wine by flow-injection analysispor
dc.typejournal article
dspace.entity.typePublication
person.familyNameSantos Silva Rangel
person.familyNameLima
person.givenNameAntónio Osmaro
person.givenNameJosé
person.identifierR-000-8FJ
person.identifier.ciencia-idD61D-7CFB-178A
person.identifier.ciencia-id4811-9AA9-D673
person.identifier.orcid0000-0002-6486-8947
person.identifier.orcid0000-0002-8906-9826
person.identifier.scopus-author-id7004827387
person.identifier.scopus-author-id10141079100
rcaap.rightsrestrictedAccesspor
rcaap.typearticlepor
relation.isAuthorOfPublication467be022-fd9c-4549-aa48-48ebcc1098eb
relation.isAuthorOfPublication71f20aa3-d4ae-40c3-a9ef-27d88442d1e0
relation.isAuthorOfPublication.latestForDiscovery467be022-fd9c-4549-aa48-48ebcc1098eb

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
19503703.pdf
Size:
647.94 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
3.44 KB
Format:
Item-specific license agreed upon to submission
Description: