Repository logo
 
Publication

Determination of nitrate and nitrite in dairy samples by sequential injection using an in-line cadmium-reducing column

dc.contributor.authorLima, M. J. Reis
dc.contributor.authorFernandes, Sílvia M.V.
dc.contributor.authorRangel, António O.S.S.
dc.date.accessioned2010-10-11T22:24:15Z
dc.date.available2010-10-11T22:24:15Z
dc.date.issued2006
dc.description.abstractA sequential injection analysis (SIA) system for the spectrophotometric determination of nitrate in dairy samples was developed. A test portion was aspirated into a carrier solution containing ethylendiaminetetracetic acid (EDTA) and ammonium buffer, which flowed into a copperized cadmium reduction column installed in-line for the determination of the nitrate plus nitrite contents of samples. For the nitrite determination, another test portion of sample was aspirated and directly sent to the detector without reduction. Nitrate content was calculated from the difference between nitrate plus nitrite (expressed as nitrite) and nitrite content. The spectrophotometric determination is based on the Griess reaction. The proposed method was used to test several dairy samples (ultrapasteurized milk with 1.7% milk fat, whey, raw bovine milk and several cheese varieties). Results were statistically in good agreement with those provided by the reference procedure, with a detection limit of 0.15 mgL 1. A sampling rate of 21 determinations per hour can be achieved with this procedure.por
dc.description.versioninfo:eu-repo/semantics/publishedVersion
dc.identifier.citationLIMA, M.J. Reis ; FERNANDES, Sílvia M.V. ; RANGEL, António O.S.S. - Determination of nitrate and nitrite in dairy samples by sequential injection using an in-line cadmium-reducing column. International Dairy Journal. ISSN 0958-6946. Vol. 16, n.º 12 (2006), p. 1442–1447por
dc.identifier.doi10.1016/j.idairyj.2005.11.010
dc.identifier.urihttp://hdl.handle.net/10400.14/2852
dc.language.isoengpor
dc.publisherElsevierpor
dc.subjectSequential injectionpor
dc.subjectCopperized cadmium columnpor
dc.subjectNitratepor
dc.subjectNitritepor
dc.subjectDairy samplespor
dc.titleDetermination of nitrate and nitrite in dairy samples by sequential injection using an in-line cadmium-reducing columnpor
dc.typejournal article
dspace.entity.typePublication
person.familyNameSantos Silva Rangel
person.givenNameAntónio Osmaro
person.identifier.ciencia-idD61D-7CFB-178A
person.identifier.orcid0000-0002-6486-8947
person.identifier.scopus-author-id7004827387
rcaap.rightsrestrictedAccesspor
rcaap.typearticlepor
relation.isAuthorOfPublication467be022-fd9c-4549-aa48-48ebcc1098eb
relation.isAuthorOfPublication.latestForDiscovery467be022-fd9c-4549-aa48-48ebcc1098eb

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
1-s2.0-S0958694605002529-main.pdf
Size:
178.29 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: