Repository logo
 
Publication

Development and psychometric property testing of a skin tear knowledge assessment instrument (OASES) in 37 countries

dc.contributor.authorVan Tiggelen, Hanne
dc.contributor.authorAlves, Paulo
dc.contributor.authorAyello, Elizabeth
dc.contributor.authorBååth, Carina
dc.contributor.authorBaranoski, Sharon
dc.contributor.authorCampbell, Karen
dc.contributor.authorDunk, Ann Marie
dc.contributor.authorGloeckner, Mary
dc.contributor.authorHevia, Heidi
dc.contributor.authorHolloway, Samantha
dc.contributor.authorIdensohn, Patricia
dc.contributor.authorKaradağ, Ayişe
dc.contributor.authorLangemo, Diane
dc.contributor.authorLeBlanc, Kimberly
dc.contributor.authorOusey, Karen
dc.contributor.authorPokorná, Andrea
dc.contributor.authorRomanelli, Marco
dc.contributor.authorSantos, Vera Lucia Conceição de Gouveia
dc.contributor.authorSmet, Steven
dc.contributor.authorWilliams, Ann
dc.contributor.authorWoo, Kevin
dc.contributor.authorVan Hecke, Ann
dc.contributor.authorVerhaeghe, Sofie
dc.contributor.authorBeeckman, Dimitri
dc.date.accessioned2021-01-06T12:21:15Z
dc.date.available2021-01-06T12:21:15Z
dc.date.issued2021
dc.description.abstractAim: To develop and psychometrically evaluate a skin tear knowledge assessment instrument (OASES). Design: Prospective psychometric instrument validation study. Method: The skin tear knowledge assessment instrument was developed based on a literature review and expert input (N = 19). Face and content validity were assessed in a two-round Delphi procedure by 10 international experts affiliated with the International Skin Tear Advisory Panel (ISTAP). The instrument was psychometrically tested in a convenience sample of 387 nurses in 37 countries (April–May 2020). Validity of the multiple-choice test items (item difficulty, discriminating index, quality of the response alternatives), construct validity, and test–retest reliability (stability) were analysed and evaluated in light of international reference standards. Results: A 20-item instrument, covering six knowledge domains most relevant to skin tears, was designed. Content validity was established (CVI = 0.90–1.00). Item difficulty varied between 0.24 and 0.94 and the quality of the response alternatives between 0.01–0.52. The discriminating index was acceptable (0.19–0.77). Participants with a theoretically expected higher knowledge level had a significantly higher total score than participants with theoretically expected lower knowledge (p < .001). The 1-week test-retest intraclass correlation coefficient (ICC) was 0.83 (95% CI = 0.78– 0.86) for the full instrument and varied between 0.72 (95% CI = 0.64–0.79) and 0.85 (95% CI = 0.81–0.89) for the domains. Cohen's Kappa coefficients of the individual items ranged between 0.21 and 0.74. Conclusion: The skin tear knowledge assessment instrument is supported by acceptable psychometric properties and can be applied in nursing education, research, and practice to assess knowledge of healthcare professionals about skin tears. Impact: Prevention and treatment of skin tears are a challenge for healthcare professionals. The provision of adequate care is based on profound and up-to-date knowledge. None of the existing instruments to assess skin tear knowledge is psychometrically tested, nor up-to-date. OASES can be used worldwide to identify education, practice, and research needs and priorities related to skin tears in clinical practice.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationTiggelen, H. V., Alves, P., Ayello, E., Bååth, C., Baranoski, S., Campbell, K., Dunk, A. M., Gloeckner, M., Hevia, H., Holloway, S., Idensohn, P., Karadağ, A., Langemo, D., LeBlanc, K., Ousey, K., Pokorná, A., Romanelli, M., Santos, V. L. C. D. G., Smet, S., ... Beeckman, D. (2021). Development and psychometric property testing of a skin tear knowledge assessment instrument (OASES) in 37 countries. Journal of Advanced Nursing, 77(3), 1609-1623. https://doi.org/10.1111/jan.14713pt_PT
dc.identifier.doi10.1111/jan.14713pt_PT
dc.identifier.eid85097508851
dc.identifier.issn0309-2402
dc.identifier.pmid33305504
dc.identifier.urihttp://hdl.handle.net/10400.14/31580
dc.identifier.wos000597215400001
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherWileypt_PT
dc.subjectInstrument developmentpt_PT
dc.subjectKnowledgept_PT
dc.subjectNursingpt_PT
dc.subjectPsychometricspt_PT
dc.subjectReliabilitypt_PT
dc.subjectSkin tearpt_PT
dc.subjectValiditypt_PT
dc.titleDevelopment and psychometric property testing of a skin tear knowledge assessment instrument (OASES) in 37 countriespt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage1623
oaire.citation.issue3
oaire.citation.startPage1609
oaire.citation.titleJournal of Advanced Nursingpt_PT
oaire.citation.volume77
person.familyNameVan Tiggelen
person.familyNameAlves
person.familyNameVan Hecke
person.familyNameBeeckman
person.givenNameHanne
person.givenNamePaulo
person.givenNameAnn
person.givenNameDimitri
person.identifier.ciencia-id1216-FE56-6E85
person.identifier.orcid0000-0002-4373-5491
person.identifier.orcid0000-0002-6348-3316
person.identifier.orcid0000-0003-3576-7159
person.identifier.orcid0000-0003-3080-8716
person.identifier.scopus-author-id23018278600
rcaap.rightsrestrictedAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublication5e688963-0eb7-42c8-afb5-8253dd616630
relation.isAuthorOfPublication09ae1927-4272-4ccb-87bf-9a49061799f3
relation.isAuthorOfPublicationd9804d9a-60a2-41f1-aff3-5e3e91178c25
relation.isAuthorOfPublication78477576-5866-4b3d-8ffc-ab73035bed10
relation.isAuthorOfPublication.latestForDiscovery09ae1927-4272-4ccb-87bf-9a49061799f3

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
27371702.pdf
Size:
590.97 KB
Format:
Adobe Portable Document Format