Logo do repositório
 
Miniatura indisponível
Publicação

Potentiometric determination of total nitrogen in soils by flow injection analysis with a gas-diffusion unit

Utilize este identificador para referenciar este registo.
Nome:Descrição:Tamanho:Formato: 
art-int-arb_1996_ESB_1022_Rangel_António_135.1.PDF1.54 MBAdobe PDF Ver/Abrir

Orientador(es)

Resumo(s)

A flow injection analysis (FIA) system incorporating a gas-diffusion unit and a potentiometric detector was developed for the determination of total nitrogen in soil digests. The solutions obtained from the Kjeldahl digestion of the soil samples were injected in the FIA system where ammonium was converted into ammonia. This gas diffused through a gas-permeable membrane to a buffer acceptor stream, allowing the separation of the gas from the rest of the sample. Once in contact with the buffer solution, ammonia was reconverted into ammonium and finally led to a tubular ammonium ion-selective electrode constructed for this purpose. The potentiometric detector is a PVC tubular selective electrode without inner reference solution, and with the sensor system composed of monactin in Tris (2-ethylhexyl) phosphate. Good agreement was obtained between the results provided with the developed FIA system and those from the classical Kjeldahl distillation/titration step, with relative deviations between the 2 methods always < 5%. A sampling rate of 80 determinations/h was achieved with good reproducibility for consecutive injections of soil digests (coefficients of variation < 3%).

Descrição

Palavras-chave

Ammonium ion-selective electrode

Contexto Educativo

Citação

FERREIRA, Alexandra M. R. ; LIMA, José L. F. C. ; RANGEL, António O. S. S. - Potentiometric determination of total nitrogen in soils by flow injection analysis with a gas-diffusion unit. Australian Journal of Soil Research. ISSN 1838-675X. Vol. 34, n.º 4 (1996), p. 503 - 510

Projetos de investigação

Unidades organizacionais

Fascículo