Browsing by Author "Gehrke, Sergio Alexandre"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
- Marginal bone level and clinical parameter analysis comparing external hexagon and Morse taper implants: a systematic review and meta-analysisPublication . Fuda, Samuele; Martins, Bruno Gomes dos Santos; Castro, Filipe Correia de; Heboyan, Artak; Gehrke, Sergio Alexandre; Fernandes, Juliana Campos Hasse; Mello-Moura, Anna Carolina Volpi; Fernandes, Gustavo Vicentis OliveiraThe goal of this systematic review was to verify the marginal bone loss (MBL) and other clinical parameters comparing external hexagon (EH) and Morse taper (MT) implants when they were evaluated within the same study. The focused question was, “For patients (P) treated with external connection (I) or Morse taper (C) dental implants, were there differences in the marginal bone crest maintenance after at least three months in occlusal function (O)”? As for the inclusion criteria that were considered, they included clinical studies in English that compared the MBL in implants with EH and MT, with follow-up of at least three months, that were published between 2011 and 2022; as for the exclusion criteria, they included publications investigating only one type of connection that analyzed other variables and did not report results for the MBL, reports based on questionnaires, interviews, and case reports/series, systematic reviews, or studies involving patients with a significant health problem (ASA Physical Status 3 and above). The PubMed/MEDLINE, Embase, and Web of Science databases were screened, and all of the data obtained were registered in a spreadsheet (Excel®). The Jadad scale was used to assess the quality of the studies. A total of 110 articles were initially identified; 11 were considered for full-text reading. Then, six articles (four RCTs and two prospective studies) met the eligibility criteria and were included in this study. A total of 185 patients (mean age of 59.71) were observed, and the follow-up ranged from 3 months to 36 months. A total of 541 implants were registered (267 EH and 274 MT). The survival rate ranged between 96% and 100% (the average was 97.82%). The MBL was compared among all periods studied; therefore, the common assessment period was the 12-month follow-up, presenting greater MBL for EH than for MT (p < 0.001). A mean MBL of 0.60 mm (95% CI 0.43–0.78) was found after the same period. BoP was reported in 5 studies and plaque index was reported in 4 (2 with more than 30%). Deep PD was observed in three studies. High heterogeneity was observed (I2 = 85.06%). Thus, within the limitation of this review, it was possible to conclude that there is higher bone loss in EH than in MT implants when evaluating and comparing this variable within the same study. However, the results must be carefully interpreted because of this review’s limited number of clinical studies, the short assessment period, and the high heterogeneity found.
- A new design of a multifunctional abutment to morse taper implant connection: experimental mechanical analysisPublication . Gehrke, Sergio Alexandre; Dedavid, Berenice Anina; Fernandes, Gustavo Vicentis de OliveiraThe objective of this study was to evaluate a new design of multifunctional abutment for Morse taper implant connections, relative to the retentive stability after the application of cyclic loads in cemented and screwed crowns. Multifunctional abutments with two different angulations in the seating portion of the crown were tested, forming 2 groups (n = 30 samples per group): Group Abut11, where Smart abutments with an angle of 11.42° were used; Group Abut5, where Ideale abutments with an angle of 5° were used. Fifteen samples from each group received cemented crowns (CC) and another fifteen screwed crowns (SC). All crown samples were subjected to the mechanical cycling test at 360,000 cycles at a frequency of 4 Hz and 150 N of the load. The samples with CC were subjected to the tensile test to remove the crowns, while in the samples with SC, the detorque value of the fastening crown screws was measured. The mean tensile strength value of CC in the Abut11 group was 131.9 ± 13.5 N and, in the Abut5 group was 230.9 ± 11.3 N; while the detorque mean value in samples with SC 5.8 ± 1.8 N for the Abut11 group and, 7.6 ± 1.1 N for Abut5 group. Significant statistical differences were found between the two groups in both situations tested (p < 0.05). The multifunctional abutments, presenting a lesser angulation of the crown-seating portion, showed higher values of retention of the CC and a lesser screw loosening of torque of the fixing screws in the SC after the application of cyclic loads when compared to the abutments with more angulation in the crown-seating portion.