Publication
Intraindividual optic nerve sheath variation and intracranial pressure changes: a systematic review and meta-analysis
| dc.contributor.author | Azevedo, Henrique | |
| dc.contributor.author | Neto, Lia Lucas | |
| dc.contributor.author | Berhanu, David | |
| dc.date.accessioned | 2025-09-22T09:41:47Z | |
| dc.date.available | 2025-09-22T09:41:47Z | |
| dc.date.issued | 2025-09-01 | |
| dc.description.abstract | Background and Purpose: To review the existing evidence on multiple timepoint assessments of optic nerve sheath diameter (ONSD) as an indicator of intraindividual variation of intracranial pressure (ICP). Methods: A systematic search identified studies assessing intraindividual variation in ICP through multiple timepoint measurements of ONSD using ultrasonography. Meta-analysis of studies assessing intraindividual correlation coefficients between ONSD and ICP was performed using a random effects model, and we calculated the weighted correlation coefficient for the expected change in ICP associated with variations in ONSD. Results: A total of five studies, comprising 157 patients, were included in the review. ONSD was compared with invasive ICP measurement methods at multiple timepoints. Meta-analysis of intraindividual ONSD–ICP correlation demonstrated a correlation coefficient of 0.62 (CI: 0.50–0.71). Individual linear correlation analyses were performed in two of the studies, yielding correlation coefficients ranging from 0.79 to 1.00; however, widely variable individual slopes were found (1.51–41.43 mm/mmHg). ONSD variations ranged from 0.12 to 3.30 mm per 5 mmHg change in ICP, with a variation of 0.55 mm in adults with hypoxic brain injury and 0.77 mm in children with idiopathic intracranial hypertension. Conclusions: Our findings indicate that ONSD significantly correlates with ICP, and longitudinal intraindividual assessment shows a predominantly linear correlation between both variables. A personalized ONSD–ICP correlation equation may enable accurate ICP prediction, making ONSD a useful tool for follow-up in patients with previous invasive ICP measurements, when adjusted to each patient's characteristics and pathologies. | eng |
| dc.identifier.citation | Azevedo, H., Neto, L. L., & Berhanu, D. (2025). Intraindividual optic nerve sheath variation and intracranial pressure changes: a systematic review and meta-analysis. Journal of Neuroimaging, 35(5), Article e70083. https://doi.org/10.1111/jon.70083 | |
| dc.identifier.doi | 10.1111/jon.70083 | |
| dc.identifier.eid | 105015054178 | |
| dc.identifier.issn | 1051-2284 | |
| dc.identifier.other | 2ecf6b37-263f-4449-8cfa-ed0ae281003c | |
| dc.identifier.pmid | 40916062 | |
| dc.identifier.uri | http://hdl.handle.net/10400.14/55053 | |
| dc.language.iso | eng | |
| dc.peerreviewed | yes | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc/4.0/ | |
| dc.subject | Intracranial pressure | |
| dc.subject | Optic nerve sheath | |
| dc.subject | Optic nerve sheath diameter | |
| dc.subject | Ultrasonography | |
| dc.title | Intraindividual optic nerve sheath variation and intracranial pressure changes: a systematic review and meta-analysis | eng |
| dc.type | review article | |
| dspace.entity.type | Publication | |
| oaire.citation.issue | 5 | |
| oaire.citation.title | Journal of Neuroimaging | |
| oaire.citation.volume | 35 | |
| oaire.version | http://purl.org/coar/version/c_970fb48d4fbd8a85 |
Files
Original bundle
1 - 1 of 1
