Utilize este identificador para referenciar este registo: http://hdl.handle.net/10400.14/6964
Título: Critical evaluation of restrictions used to optimize sterilization processing conditions
Autor: Silva, C. L. M.
Korczak, K.
Data: 1994
Citação: SILVA, C. L. M. ; KORCZAK, K. - Critical evaluation of restrictions used to optimize sterilization processing conditions. In Bath Food Process Engineering Conference, 4, Bath, UK, 19-21 September, 1994 - 4th Bath Food Process Engineering Conference : Book of Abstracts. [S.l. : s.n., 1994]. 8 p.
Resumo: A computer program, using a finite differences method, was developed to model the heat sterilization for cylindrical packaged conduction heating foods. This program was introduced into an optimization routineto calculate optimum processing conditions, maximizing the surface or the volume average quality, using different restrictions. Depending on the pack dimensions and the heating rate of the product the least-lethality point is at the geometric center or along the radius or the vertical axis. Therefore, sterility values specified at the center and at the least-Iethality point were used as sterility criteria for calculating optimum conditions. The effect of an integrated sterility value constraint on optimal temperature was also investigated. Depending on the product thermal properties, processing conditions and target lethality the optimum temperature calculated using the sterility value at the center as restriction can overestimate the correet valueby as much as 4°C.
Peer review: no
URI: http://hdl.handle.net/10400.14/6964
Aparece nas colecções:ESB - Artigos em Actas / Papers in proceedings

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
trab-int_1994_ESB_1294_Silva_Cristina_01.1.pdf.pdf4,11 MBAdobe PDFVer/Abrir


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpace
Formato BibTex MendeleyEndnote Degois 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.